Ohaus DEFENDER 5000 BENCH SCALES Manual en User Manual
Page 24
EN-22
5000 Series Indicators
3.4.7 Auto-Tare
Set the Automatic Tare functionality.
OFF = Automatic Tare is disabled.
ON = the first stable gross weight will be tared.
ACCEPt = when the application mode is CHECK, stable gross weight that is within the
Checkweigh accept limits will be tared.
3.4.8 Retain Weight Data
Set the Retain Weight Data functionality.
OFF = Disabled.
ON = When power is turned on, the displayed weight is based on the last stored zero (Zero
button or “Z” command).
3.4.9 Legal for Trade
Set the legal for trade status.
OFF = standard operation
ON = operation complies with weights and measures regulations
NOTE: When Legal for Trade is set to ON, the Menu settings are affected as follows:
• Calibration functions are hidden except for Calibration Test.
• Capacity is read-only.
• Range, Graduation, Power On unit, Auto-Tare, Retain Zero, Gross Indication, Print Output, Unit and Mode
settings are locked at their current settings.
• Zero Range is locked at 2%.
• Stable Range is locked at 1d.
• Auto-Zero Tracking is set to 0.5d.
• Continuous Print is disabled.
• IP and CP RS232 commands are disabled.
NOTE: When Legal for Trade is set to ON, it is necessary to set the security switch to ON before exiting the
menu. If the security switch is not set to ON, the message “NO.SW” is displayed and the indicator returns to
the menu.
When Accept is selected, set the current delay time is displayed.
Settings:
OFF
= automatic tare takes affect immediately
0.5, 1, 2 or 5 = automatic tare takes affect after the selected delay period (in seconds).