Ohaus DEFENDER 5000 BENCH SCALES Manual en User Manual
Page 27

EN-25
5000 Series Indicators
3.5.5 Backlight
Set the display backlight functionality.
OFF = always off.
ON = always on.
AUtO = turns on when a button is pressed or the displayed weight changes.
When Auto is selected, set Backlight shut off time.
Settings:
SEt 1 = backlight turns off after 1 minute of no activity.
SEt 2 = backlight turns off after 2 minute of no activity.
SEt 5 = backlight turns off after 5 minute of no activity.
3.5.6 Auto Off Timer
Set the automatic shut off functionality.
OFF
= disabled
SEt 1 = powers off after 1 minute of no activity.
SEt 2 = powers off after 2 minutes of no activity.
SEt 5 = powers off after 5 minutes of no activity.
3.5.7 Gross Indicator
Set the type of gross indicator.
OFF
= disabled
G GrOSS = the G icon is lit when gross weights are displayed.
B brutto = the B icon is lit when gross weights are displayed.
3.5.8 End Readout
Advance to the next menu.
3.6 Mode Menu
Enter this menu to activate the desired application
modes. Default settings are
bold.
Reset
No, Yes
Weigh Off,
On
Count
Off, On (-> Piece weight optimization (-> On, Off))
Percent
Off, On
Dynamic
Off, Manual (-> Set 0 … Set 60), Semi-automatic
(-> Set 0 … Set 60), Automatic (-> Set 0 … Set 60)
Checkweigh
Off, On
End Mode Exit MODE menu