2 control parameters, Control parameters, Ontrol – EVS XTAccess Version 1.16 - November 2011 User Manual User Manual
Page 43: Arameters
XTAccess Version 1.16 – User’s Manual
Author: Serge Comes EVS Broadcast Equipment – November 2011
Issue 1.16.A
41
7.5.2 C
ONTROL
P
ARAMETERS
Some parameters have been added to better control the load balancing job
management. Those parameters can be changed in the registry. XTAccess must
be re-started in order to take them into account.
•
HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\Max
Running Jobs (default value = 6): Maximum amount of jobs simultaneously
processed by XTAccess. Once the limit is reached, any additional job will be
“scheduled” (in Jobs_Scheduled” folder) until an “in-progress” job is over.
•
HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\Max
IP Jobs (default value = 6): Maximum amount of jobs simultaneously
processed by XTAccess to or from a given IP address (as destination or source
XT server). Once the limit is reached, any new job involving the same IP
address will be “scheduled” (in Jobs_Scheduled” folder) until a “in-progress”
job related to this IP address is over.
Besides, in case a job related to the IP address is in status “Server Busy”, any
next job using the same IP address will stay in “Scheduled” status until all jobs
under “Server Busy” will be passed to “in-progress” status. At that time
XTAccess scans the job list “scheduled” in order to move them to “in-progress”
status. In case of XT Copy job, IP addresses of source and destination XT
server are taken into account.
•
HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\Max
XML Jobs (default value = 6): Maximum amount of jobs simultaneously
processed by XTAccess per XML scan folder. This amount defined the
maximum amount of XML files that will be processed by an XML scan folder,
possibly after several scan processes (depending on Max Scan Running Jobs
parameter – see below).
•
HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\Max
XML Jobs Per Scan (default value = 6): Maximum amount of jobs
simultaneously loaded by XTAccess per scan processes. This amount defined
the maximum amount of files that will be loaded by a scan process of the given
folder.
•
HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\XML
Scan Timeout (default value = 250): Time delay (in milliseconds) between two
successive scan processes, provided that the “Max XML Jobs” parameter is not
already reached.
•
HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\XML
Scan Jobs Timeout (default value = 5000): Time delay (in milliseconds)
between the treatment of two successive XML jobs.
•
HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\IP
Retry (default value = 12): Maximum amount of attempts to connect to an IP
address of a XT server which does not reply.
•
HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\IP
Retry Timeout (default value = 5000): Time delay (in milliseconds) between
two successive attempts to connect to an IP address which does not reply.
•
HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\IP
Retry Timeout (default value = 5000): Time delay (in milliseconds) between
two successive attempts to connect to an IP address which does not reply.
•
HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\Max
Transcoding Jobs (default value = 1): Maximum amount of transcoding jobs