beautypg.com

Example, 5 gpis out advance and duration, Gpi out advance – EVS MulticamLSM Version 10.03 - July 2010 Configuration Manual User Manual

Page 89: Gpi pulse duration, Tion, 5 gpi, Dvance and, Uration

background image

Issue
10.03.C

EVS

Multicam – Version 10.03 – Configuration Manual

EVS Broadcast Equipment SA – July 2010

82

Example

Users can select all types of GPIs. The behavior varies accordingly:

Before

the

IN

On Replace
IN

Between IN
and OUT

On Replace
OUT

After the
OUT

Close-
High

Low

High

High

Low

Low

Open-
Low

High

Low

Low

High

High

Close-
High
Pulse

Low

High Pulse

Low

High Pulse

Low

Open-
Low
Pulse

High

Low Pulse

High

Low Pulse

High

3.19.5 GPI

S

OUT

A

DVANCE AND

D

URATION


GPI OUT Settings p.8.6
GPI# Advance Duration
1 [F1]Disable [F5]01s00fr
2 [F2]Disable [F6]01s00fr
3 [F3]Disable [F7]01s00fr
4 [F4]Disable [F8]01s00fr

[Menu]Quit [Clr+F_]Dft [F9]PgUp [F0]PgDn


GPI OUT Settings p.8.7
GPI# Advance Duration
5 [F1]Disable [F5]01s00fr
6 [F2]Disable [F6]01s00fr
7 [F3]Disable [F7]01s00fr
8 [F4]Disable [F8]01s00fr

[Menu]Quit [Clr+F_]Dft [F9]PgUp [F0]PgDn

GPI OUT Advance

Possible values: Disable (default) / 00s01fr to 02s00fr

Possible values: up to 2 seconds, frame by frame (like GPI delay)

When a GPI out advance setting is set (for instance 2 fr.), the GPI OUT is sent 2
frames in advance.

GPI Pulse Duration

Possible values: Disable / 00s01fr to 02s00fr. Default: 01s00fr.

Set the default duration for pulse GPIs.