XTAccess Version 1.19 – User Manual

EVS Broadcast Equipment – November 2012

36

7.5.2 Control Parameters

Some parameters have been added to better control the load balancing job management.

Those parameters can be changed in the registry. XTAccess must be re-started in order

to take them into account.

HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\Max

Running Jobs (default value = 6): Maximum amount of jobs simultaneously

processed by XTAccess. Once the limit is reached, any additional job will be

“scheduled” (in Jobs_Scheduled” folder) until an “in-progress” job is over.

HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\Max IP

Jobs (default value = 6): Maximum amount of jobs simultaneously processed by

XTAccess to or from a given IP address (as destination or source XT server). Once

the limit is reached, any new job involving the same IP address will be “scheduled” (in

Jobs_Scheduled” folder) until a “in-progress” job related to this IP address is over.
Besides, in case a job related to the IP address is in status “Server Busy”, any next

job using the same IP address will stay in “Scheduled” status until all jobs under

“Server Busy” will be passed to “in-progress” status. At that time XTAccess scans the

job list “scheduled” in order to move them to “in-progress” status. In case of XT Copy

job, IP addresses of source and destination XT server are taken into account.

HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\Max

XML Jobs (default value = 6): Maximum amount of jobs simultaneously processed by

XTAccess per XML scan folder. This amount defined the maximum amount of XML

files that will be processed by an XML scan folder, possibly after several scan

processes (depending on Max Scan Running Jobs parameter – see below).

HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\Max

XML Jobs Per Scan (default value = 6): Maximum amount of jobs simultaneously

loaded by XTAccess per scan processes. This amount defined the maximum amount

of files that will be loaded by a scan process of the given folder.

HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\XML

Scan Timeout (default value = 250): Time delay (in milliseconds) between two

successive scan processes, provided that the “Max XML Jobs” parameter is not

already reached.

HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\XML

Scan Jobs Timeout (default value = 5000): Time delay (in milliseconds) between the

treatment of two successive XML jobs.

HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\IP

Retry (default value = 12): Maximum amount of attempts to connect to an IP address

of a XT server which does not reply.

HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\IP

Retry Timeout (default value = 5000): Time delay (in milliseconds) between two

successive attempts to connect to an IP address which does not reply.

HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\IP

Retry Timeout (default value = 5000): Time delay (in milliseconds) between two

successive attempts to connect to an IP address which does not reply.

HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\Max

Transcoding Jobs (default value = 1): Maximum amount of transcoding jobs

simultaneously processed by XTAccess (rendering of playlists included)

HKEY_CURRENT_USER\Software\EVS Broadcast Equipment\XTAccess\Max

Meta Jobs (default value = 1): Maximum amount of Meta jobs (Backup of playlist)

simultaneously processed by XTAccess