Scale installation, Installation procedure – ACU-RITE Micro-Line M User Manual
Page 49

MICRO-LINE
Reference Manual
SCALE INSTALLATION
46
Installation Procedure
These steps apply to typical mounting conditions. Although this
may not pictorially represent your application, your installation pro-
cedure should follow these steps.
ACU-RITE bracket kit instructions supersede this
section.
•
Adjust drill depths and fastener lengths as required.
•
Contact your Authorized ACU-RITE Distributor if assistance
is required.
First Steps:
1. Move the axis to its center of travel.
2. Mark the axis location so that it can be re-centered easily.
3. Slide the reading head with the alignment brackets attached,
along the scale case to the center of the scale case.
4. Locate the bottom of the end cap flush with the axis parting line.
5. Mark one end mounting hole.
6. Drill and tap the hole location 10-32 x 1/2” deep for the top
mounting form and a 1/4-20 x 1/2” deep for the end mounting
form. Attach the scale.
MLMmanual.QXD 2/12/02 5:01 PM Page 9