beautypg.com

Operation – ACU-RITE Micro-Line M User Manual

Page 16

background image

MICRO-LINE

Reference Manual

13

OPERATION

Using the

ABS/INCR

key, select the absolute (ABS) mode. Also

check that the proper measurement (inch or mm) is selected.

Move the tool to a known point, i.e. the outside diameter of the
workpiece or the face of the workpiece.

Press the

ZERO

key for the axis (X, Y or Z) you are entering a

dimension for.

Using the keypad, enter the distance from your tool’s current
location to the point you want to establish as the datum. Include a
decimal point (.) and minus (-) sign when necessary.

Press the

ZERO

key for another axis, or press

ENTER

to return to

the DRO display.

To set the datum using an offset:

To set the datum at the tool’s current position:

Position the workpiece on the table. Move the table until the tool is
centered on the edge of the workpiece at the location where you
would like to establish the datum.

Using the

ABS/INCR

key, select the absolute (ABS) mode.

Press the X-axis

ZERO

key twice to establish the current X-axis

position as the datum. Repeat for the Y- and Z-axes.

If you are using 5µm (0.0002”) scales (international units only),

MICRO-LINE

can recall your last datum position each time you

power up the system. Refer to pg. 38 for the proper procedure.

MLMmanual.QXD 2/12/02 5:01 PM Page 30