beautypg.com

Setup linear error compensation – ACU-RITE Micro-Line M User Manual

Page 10

background image

SETUP

Linear Error Compensation

With

MICRO-LINE

, you can compensate for machine tool wear. If you

know the linear error compensation (LEC) value in parts per million
(PPM), you can enter it directly.

If you don’t know the LEC, use the formula on the next page to determine
the value for each axis.

Move to the “Linear Error Compensation” display in the Setup
mode. (Press

SETUP

and then the

ENTER

key until the display

appears).

Press the

X

,

Y

, or

Z

key for the axis you want to change.

MICRO-LINE

will display the current LEC value for that axis.

Using the keypad, enter the linear error compensation factor
(in PPM), followed by a + or - sign. The number must be within
-9999 and 9999 (use whole numbers). The formula for calculating
the value is on the next page.

After you complete setting your LEC, press ENTER to continue with
setup or press ENTER then SETUP to return to the normal DRO
display.

To change the linear error compensation:

7

MLMmanual.QXD 2/12/02 5:01 PM Page 18