ECP+EPP The parallel port operates in the extended capabilities port (ECP) mode. The ECP mode supports
bi-directional communication between the system and the parallel port device and the transmission rates between the two are
much faster than the Normal mode. The parallel port is also be compatible with EPP devices described above.
Parallel Port IRQ [IRQ7]
Use the Parallel Port IRQ selection to set the parallel port interrupt address.
IRQ5
IRQ5 is assigned as the parallel port interrupt address
IRQ7
DEFAULT
IRQ7 is assigned as the parallel port interrupt address
Serial Port3 Address [3E8]
Use the Serial Port3 Address option to select the base addresses for serial port 3
Disabled
No base address is assigned to serial port 3
3E8
DEFAULT
Serial port 3 I/O port address is 3E8
2E8
Serial port 3 I/O port address is 2E8
2E0
Serial port 3 I/O port address is 2E0
Serial Port4 Address [2E8]
Use the Serial Port4 IRQ option to select the interrupt address for serial port 4.
Disabled
No base address is assigned to serial port 3
3E8
Serial port 4 I/O port address is 3E8
2E8
DEFAULT
Serial port 4 I/O port address is 2E8
2E0
Serial port 4 I/O port address is 2E0
Serial Port5 Address [2F0]
Use the Serial Port5 IRQ option to select the interrupt address for serial port 5.
Disabled
No base address is assigned to serial port 5
3E8
Serial port 5 I/O port address is 3E8
2E8
Serial port 5 I/O port address is 2E8
2F0
DEFAULT
Serial port 5 I/O port address is 2F0
2E0
Serial port 5 I/O port address is 2E0
Select RS232 or RS422/485 [RS/232]
Use the Select RS232 or RS422/485 option to select the Serial Port 5 signaling mode.
RS232 DEFAULT
Serial Port 2 signaling mode is RS-232
RS422/485
Serial Port 2 signaling mode is RS-422 or RS-485
Serial Port6 Address [2D8]
Use the Serial Port6 IRQ option to select the interrupt address for serial port 6.
Disabled
No base address is assigned to serial port 6
3E8
Serial port 6 I/O port address is 3E8
2E8
Serial port 6 I/O port address is 2E8
2F0
Serial port 6I/O port address is 2F0
2E0
DEFAULT