beautypg.com

Schneider Electric XY2 CH User Manual

Page 6

background image

4

SETTING (fig. 2)

1. Cut the cable to the correct length at the push button, leaving sufficient strip length so that it can be wound

up

 - correct: min. 1.5 turns.

2. Engage the cable on the tensioner

.

3. Turn the adjustment nut until the index is centered

.

(b): index - (c): allowed operating zone (fig. 5a and 5b)

4. Arm the device by pressing the switch: you should hear a "click"

.

5. Actuate the device by pulling the cable

.

6. Repeat steps 4 and 5 once more.
7. Check the position of the index

 and repeat steps 3 to 6 if required.

(d): green - (e): yellow

8. To release the cable: push the hooking ring with your finger

, then untighten the nut as required, based

on the maximum allowable operating temperature variance (fig. 3) and take into account the table from the
fig. 4.

NOTE: You can compensate for expansion/contraction of the cable by adjusting the configuration to take
account of temperature variations:
• Fig.5a: anticipation of a fall in temperature,
• Fig.5b: anticipation of a rise in temperature.

RISK OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
• Switch off the power supply of the device.
• Use appropriate personal protective equipment (PPE) and follow the relevant working instructions for

electrical environments. See NFPA 70E.

• Always use an appropriate electrical measuring device to confirm that the entire installation is powered

down.

Failure to follow these instructions will result in death or serious injury.

RISK OF FALL, COLLISION OR CRUSHING
Configure the device on the basis of the ambient temperature.
Failure to follow these instructions can result in death, serious injury, or equipment damage.

RISK OF UNINTENDED EQUIPMENT OPERATION
Check that the device, cable and accessories are securely mounted in place.
Failure to follow these instructions will result in death or serious injury.

RISK OF PHYSICAL INJURY
Always check the product functioning before restarting.
Failure to follow these instructions will result in death or serious injury.

DANGER

DANGER

WARNING

DANGER

DANGER

schneider.fm Page 4 Friday, May 31, 2013 2:08 PM