INSTALLATION (fig. 1)
1. Mount the device
solidly to a rigid support using cylindrical head screw M6 CHC, through holes
(tightening torque = 4±0.5 Nm / 2.95±0.369 lb.ft).
2. Mount the cable guides
firmly to rigid elements. Ensure that the product is anchored along the same axis
as the cable.
3. Attach the end spring
to a rigid element.
4. Connect the strip cable
to the end spring using a cable clamp .
5. Pass the cable
through all the cable guides .
NOTE:
1) The list of accessories and springs can be found in the Schneider Electric catalog.
2) A support or element may be described as "rigid" if it is capable of supporting a load of 2,000 N.
RISK OF ELECTRICAL SHOCK, EXPLOSION OR ARC FLASH
• Switch off the power supply of the element acting as support.
• Take care not to damage the parts of the support that are normally powered.
• Visually inspect the good condition of the product.
• Use appropriate personal protective equipment (PPE) and follow the relevant working instructions for
electrical environments. See NFPA 70E.
• Always use an appropriate electrical measuring device to confirm that the entire installation is powered
down.
Failure to follow these instructions will result in death or serious injury.
RISK OF UNINTENDED EQUIPMENT OPERATION
• Use Schneider Electric accessories only.
• Ensure that the product is anchored along the same axis as the cable.
• Mount the product to its support using 2 screws.
• An end spring must be used.
• Place the cable guides no less than 1 meter (3.28 feet) and no more than 5 meters (16.4 feet) apart from
each other.
• Strip the cable at the cable clamp points.
• Remove all objects placed on the cable or masking it.
• Ensure that the cable is free to move.
Failure to follow these instructions will result in death or serious injury.
RISK OF PHYSICAL INJURY
• Inspect the cable in its entirety to identify the reason for the emergency stop order before restarting.
• Always check the product functioning before restarting.
Failure to follow these instructions will result in death or serious injury.
RISK OF FALL, COLLISION OR CRUSHING
• Secure the cable traction zone.
• Ensure that the cable is accessible along the entire traction zone.
Failure to follow these instructions can result in death, serious injury, or equipment damage.