14 dy060 indoor sound power levels, Vertical ducted inlet), 15 dy060 indoor sound power levels – York DY 036 User Manual
Page 13: Vertical ducted discharge)
343615-YTG-A-0807
Unitary Products Group
13
TABLE 14: DY060 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED INLET)
UNIT DESCRIPTION / MODEL
CONFIGURATION
Indoor Blower Speed (RPM)
Blower Static Pressure (IWG)
Airflow (CFM)
Blower Motor BHP
63
77
86
79
88
81
86
83
87
125
69
70
70
72
71
73
72
72
250
56
63
56
58
64
72
63
69
500
50
52
48
49
57
59
53
56
1000
48
51
44
45
57
58
49
52
2000
43
47
39
41
54
57
47
50
4000
47
49
40
41
55
61
47
52
8000
46
47
44
45
51
57
47
49
DY060 / 5 Ton
Vertical Ducted Inlet
834
840
1171
1194
0.2
0.6
0.2
1.3
1525
1019
2624
1256
0.61
0.44
1.43
0.83
Octave Center Freq.
ID Blower
Only (dB)
Cooling
Operation
2
(dB)
ID Blower
Only (dB)
4. Test duct termination is flush with reverberation room wall.
5. Duct end (sound reflection) correction: (11, 6, 3, 1, 0, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 4k, 8k) Hz.
Cooling
Operation
2
(dB)
1. Tested in accordance with ARI Standard 260. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Eq uipment .
2. Cooling Operation – ID blower, compressor and outdoor fan operating.
3. Test Duct Dimension: 12 in. wide x 18 in. high x 8 ft. long (0.30m x 0.46m x 2.44m).
Cooling
Operation
2
(dB)
ID Blower
Only (dB)
Cooling
Operation
2
(dB)
ID Blower
Only (dB)
TABLE 15: DY060 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED DISCHARGE)
UNIT DESCRIPTION / MODEL
CONFIGURATION
Indoor Blower Speed (RPM)
Blower Static Pressure (IWG)
Airflow (CFM)
Blower Motor BHP
63
83
88
82
88
91
91
85
88
125
78
78
75
76
85
85
79
79
250
66
67
62
62
77
78
70
72
500
59
60
54
54
70
70
61
61
1000
57
58
51
51
68
68
57
58
2000
51
52
45
45
62
63
52
53
4000
54
54
47
47
65
66
55
56
8000
52
52
46
47
65
66
52
53
DY060 / 5 Ton
Vertical Ducted Discharge
834
840
1171
1194
0.2
0.6
0.2
1.3
1525
1019
2624
1256
0.61
0.44
1.43
0.83
Cooling
Operation
2
(dB)
ID Blower
Only (dB)
Octave Center Freq.
ID Blower
Only (dB)
Cooling
Operation
2
(dB)
ID Blower
Only (dB)
4. Test duct termination is flush with reverberation room wall.
5. Duct end (sound reflection) correction: (11, 6, 3, 1, 0, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 4k, 8k) Hz.
Cooling
Operation
2
(dB)
1. Tested in accordance with ARI Standard 260. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Eq uipment .
2. Cooling Operation – ID blower, compressor and outdoor fan operating.
3. Test Duct Dimension: 12 in. wide x 18 in. high x 8 ft. long (0.30m x 0.46m x 2.44m).
Cooling
Operation
2
(dB)
ID Blower
Only (dB)