13

TABLE 14: DY060 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED INLET)

UNIT DESCRIPTION / MODEL
CONFIGURATION
Indoor Blower Speed (RPM)
Blower Static Pressure (IWG)
Airflow (CFM)
Blower Motor BHP

63

77

86

79

88

81

86

83

87

125

69

70

70

72

71

73

72

72

250

56

63

56

58

64

72

63

69

500

50

52

48

49

57

59

53

56

1000

48

51

44

45

57

58

49

52

2000

43

47

39

41

54

57

47

50

4000

47

49

40

41

55

61

47

52

8000

46

47

44

45

51

57

47

49

DY060 / 5 Ton

Vertical Ducted Inlet

834

840

1171

1194

0.2

0.6

0.2

1.3

1525

1019

2624

1256

0.61

0.44

1.43

0.83

Octave Center Freq.

ID Blower

Only (dB)

Cooling

Operation

2

(dB)

ID Blower

Only (dB)

4. Test duct termination is flush with reverberation room wall.

5. Duct end (sound reflection) correction: (11, 6, 3, 1, 0, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 4k, 8k) Hz.

Cooling

Operation

2

(dB)

1. Tested in accordance with ARI Standard 260. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Eq uipment .

2. Cooling Operation – ID blower, compressor and outdoor fan operating.

3. Test Duct Dimension: 12 in. wide x 18 in. high x 8 ft. long (0.30m x 0.46m x 2.44m).

Cooling

Operation

2

(dB)

ID Blower

Only (dB)

Cooling

Operation

2

(dB)

ID Blower

Only (dB)

TABLE 15: DY060 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED DISCHARGE)

UNIT DESCRIPTION / MODEL
CONFIGURATION
Indoor Blower Speed (RPM)
Blower Static Pressure (IWG)
Airflow (CFM)
Blower Motor BHP

63

83

88

82

88

91

91

85

88

125

78

78

75

76

85

85

79

79

250

66

67

62

62

77

78

70

72

500

59

60

54

54

70

70

61

61

1000

57

58

51

51

68

68

57

58

2000

51

52

45

45

62

63

52

53

4000

54

54

47

47

65

66

55

56

8000

52

52

46

47

65

66

52

53

DY060 / 5 Ton

Vertical Ducted Discharge

834

840

1171

1194

0.2

0.6

0.2

1.3

1525

1019

2624

1256

0.61

0.44

1.43

0.83

Cooling

Operation

2

(dB)

ID Blower

Only (dB)

Octave Center Freq.

ID Blower

Only (dB)

Cooling

Operation

2

(dB)

ID Blower

Only (dB)

4. Test duct termination is flush with reverberation room wall.

5. Duct end (sound reflection) correction: (11, 6, 3, 1, 0, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 4k, 8k) Hz.

Cooling

Operation

2

(dB)

1. Tested in accordance with ARI Standard 260. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Eq uipment .

2. Cooling Operation – ID blower, compressor and outdoor fan operating.

3. Test Duct Dimension: 12 in. wide x 18 in. high x 8 ft. long (0.30m x 0.46m x 2.44m).

Cooling

Operation

2

(dB)

ID Blower

Only (dB)