beautypg.com

Bot tom duct con nec tions, Cool ing ap pli ca tions), 6unitary products group – York D2CG User Manual

Page 6: Dce300, Blower performance, Dcg300

background image

036-21359-001-B-0302

6

Unitary Products Group

BLOWER PER FORM ANCE

- 25 TON (DCE/DCG300)

BLOWER

PULLEY

SPEED

TURNS

ESP

OUTPUT

INPUT

ESP

OUTPUT

INPUT

ESP

OUTPUT

INPUT

ESP

OUTPUT

INPUT

ESP

OUTPUT

INPUT

(rpm)

OPEN:

(iwg)

(bhp)

(kW)

(iwg)

(bhp)

(kW)

(iwg)

(bhp)

(kW)

(iwg)

(bhp)

(kW)

(iwg)

(bhp)

(kW)

975

6.0*

1.4

5.9

4.9

1.0

7.3

6.0

0.5

8.8

7.2

-

-

-

-

-

-

1005

5.0

1.6

6.2

5.1

1.2

7.7

6.3

0.7

9.2

7.6

0.1

10.9

8.9

-

-

-

1040

4.0

1.8

6.6

5.4

1.4

8.1

6.7

0.9

9.7

8.0

0.3

11.4

9.4

-

-

-

1070

3.0

2.0

6.9

5.7

1.6

8.5

7.0

1.1

10.2

8.3

0.6

11.9

9.8

-

-

-

1100

2.0

2.1

7.3

6.0

1.8

8.9

7.3

1.3

10.6

8.7

0.8

12.4

10.2

0.2

14.3

11.7

1135

1.0

2.4

7.7

6.3

2.0

9.3

7.6

1.6

11.1

9.1

1.0

13.0

10.6

0.4

14.9

12.2

1165

0.0

2.6

8.0

6.6

2.2

9.7

8.0

1.8

11.6

9.5

1.3

13.5

11.0

0.7

15.5

12.7

1140

6.0

2.4

7.7

6.3

2.1

9.4

7.7

1.6

11.2

9.2

1.1

13.1

10.7

0.5

15.0

12.3

1180

5.0

2.7

8.2

6.7

2.3

9.9

8.1

1.9

11.8

9.7

1.4

13.7

11.2

0.8

15.8

12.9

1215

4.0

2.9

8.6

7.0

2.6

10.4

8.5

2.2

12.3

10.1

1.7

14.3

11.7

1.1

16.4

13.5

1255

3.0

3.2

9.1

7.4

2.9

11.0

9.0

2.5

12.9

10.6

2.0

15.0

12.3

1.4

17.2

14.1

1290

2.0

3.4

9.5

7.8

3.1

11.5

9.4

2.7

13.5

11.1

2.2

15.6

12.8

-

-

-

1330

1.0

3.7

10.0

8.2

3.4

12.0

9.9

3.0

14.1

11.6

2.6

16.4

13.4

-

-

-

1365

0.0

3.9

10.5

8.6

3.7

12.6

10.3

3.3

14.7

12.1

2.9

17.0

13.9

-

-

-

NOTES:

Blower performance is based on cooling only unit, with fixed outdoor air, 2" T/A filters and a dry evaporator coil.
Refer to page 7 for additional static resistances.
ESP - External Static Pressure available for the supply and return air duct system. All internal unit resistances have been deducted from the total static pressure of the
blower.
* FACTORY SETTING

7500 CFM

8750 CFM

10000 CFM

11250 CFM

12500 CFM

STANDARD DRIVE:

ACCESSORY DRIVE:

DCE300

- BOT TOM DUCT CON NEC TIONS

(

COOL ING AP PLI CA TIONS)

BLOWER

PULLEY

SPEED

TURNS

ESP

OUTPUT

INPUT

ESP

OUTPUT

INPUT

ESP

OUTPUT

INPUT

ESP

OUTPUT

INPUT

ESP

OUTPUT

INPUT

(rpm)

OPEN:

(iwg)

(bhp)

(kW)

(iwg)

(bhp)

(kW)

(iwg)

(bhp)

(kW)

(iwg)

(bhp)

(kW)

(iwg)

(bhp)

(kW)

975

6.0*

1.2

5.9

4.9

0.5

7.3

6.0

-

-

-

-

-

-

-

-

-

1005

5.0

1.4

6.2

5.1

0.7

7.7

6.3

-

-

-

-

-

-

-

-

-

1040

4.0

1.6

6.6

5.4

0.9

8.1

6.7

0.2

9.7

8.0

-

-

-

-

-

-

1070

3.0

1.8

6.9

5.7

1.1

8.5

7.0

0.4

10.2

8.3

-

-

-

-

-

-

1100

2.0

2.0

7.3

6.0

1.3

8.9

7.3

0.6

10.6

8.7

-

-

-

-

-

-

1135

1.0

2.2

7.7

6.3

1.6

9.3

7.6

0.8

11.1

9.1

-

-

-

-

-

-

1165

0.0

2.4

8.0

6.6

1.8

9.7

8.0

1.0

11.6

9.5

0.2

13.5

11.0

-

-

-

1140

6.0

2.2

7.7

6.3

1.6

9.4

7.7

0.9

11.2

9.2

-

-

-

-

-

-

1180

5.0

2.5

8.2

6.7

1.9

9.9

8.1

1.2

11.8

9.7

0.3

13.7

11.2

-

-

-

1215

4.0

2.7

8.6

7.0

2.1

10.4

8.5

1.4

12.3

10.1

0.6

14.3

11.7

-

-

-

1255

3.0

3.0

9.1

7.4

2.4

11.0

9.0

1.7

12.9

10.6

0.9

15.0

12.3

-

-

-

1290

2.0

3.2

9.5

7.8

2.7

11.5

9.4

2.0

13.5

11.1

1.2

15.6

12.8

-

-

-

1330

1.0

3.5

10.0

8.2

3.0

12.0

9.9

2.3

14.1

11.6

1.5

16.4

13.4

-

-

-

1365

0.0

3.7

10.5

8.6

3.2

12.6

10.3

2.6

14.7

12.1

1.8

17.0

13.9

-

-

-

NOTES:

Blower performance is based on cooling only unit, with fixed outdoor air, 2" T/A filters and a dry evaporator coil.
Refer to page 7 for additional static resistances.
ESP - External Static Pressure available for the supply and return air duct system. All internal unit resistances have been deducted from the total static pressure of the
blower.
* FACTORY SETTING

STANDARD DRIVE:

ACCESSORY DRIVE:

7500 CFM

8750 CFM

10000 CFM

11250 CFM

12500 CFM

BLOWER PERFORMANCE

- 25 TON (DCE/DCG300)

DCG300

- BOT TOM DUCT CON NEC TIONS

(

COOL ING AP PLI CA TIONS)

This manual is related to the following products: