Status annunciators, On: the supply output is enabled (green), Off: the supply output has been disabled (green) – Xantrex Technology XPR 150-40 User Manual
Page 21: Lcl: the supply is in local control mode (green), Rmt: the supply is in remote program mode (green), Figure 1.2, Front panel display, status annunciators

About The XPR Power Supply
Status Annunciators
Release 1.1
19
Status Annunciators
Figure 1.2 Front Panel Display, Status Annunciators
1. AC: The AC input is out of range and has caused the output of the supply to be
shut down (red)
2. OTP: The internal Over Temperature Protection threshold has been exceeded,
disabling the supply output until the sensors cool to within the normal operating
temperature range (red)
3. INT: The external shutdown line has been asserted, disabling the output of the
supply (green)
4. OVP: The output Over Voltage Protection threshold have been exceeded,
latching the supply output off (red)
5. SNS: The remote sense line protection circuit has been activated, latching the
supply output off (red)
6. ON: The supply output is enabled (green)
7. OFF: The supply output has been disabled (green)
8. LCL: The supply is in Local control mode (green)
9. RMT: The supply is in Remote program mode (green)
10. CV: The supply is operating in Constant Voltage mode (green)
11. CC: The supply is operating in Constant Current mode (green)