This table provides frequently asked questions (FAQs) on
PSII
:
Question
Answer
Are there any differences in
functionality between a ZebraNet
PSII
with an EPL based printer
and with a ZebraLink enabled
ZPL printer?
Yes.
• In a ZebraLink environment, with either a
web browser or with the ZebraNet View Util-
ities, there are a variety of web pages which
display a wealth of status information regard-
ing both the ZebraLink printer and its Zebra-
Net
PSII
. However, when used with an EPL
printer, such as the LP/TLP 2844, the web
pages for printer status are not available at
this time, only the web page showing status
of the
PSII
are displayed. The
PSII
can be
easily configured. However, printer configu-
ration information regarding the EPL printer
is not available via the ZebraNet Utilities.
• Error conditions: Using ZebraNet Alert, an
EPL printer can be configured to use multiple
different IP addresses to report the following
Alert status conditions: on-line, off-line,
paper out.
• For EPL: only two destinations can be con-
figured to report error messages (online,
offline, and paper out) using SMTP email
alert – serial and parallel port destinations are
not supported.
Can the internal ZebraNet
PSII
option work on a computer
network that is running both
TCP/IP and IPX protocols
simultaneously?
Yes.
The ZebraNet
PSII
runs all of its available
protocols simultaneously. This means that the
ZebraNet
PSII
can run on mixed networks
such as a network using Microsoft, UNIX,
and Novell NetWare operating systems.