Cooling capacity - with air handler coils – York 12 SEER H*RC018 THRU 060 User Manual
Page 6
036-21137-004 Rev. C (0505)
6
Unitary Products Group
- = Not applicable.
COOLING CAPACITY - With Air Handler Coils
UNIT MODEL
AIR HANDLER
COIL
1
MODEL
COOLING
MODEL
ELECTRIC
2
HEAT KW
W
RATED
CFM
NET MBH
SEER
W/O TXV
SEER
WITH TXV
3
EER
TOTAL
SENS.
1 PH 12 SEER AC WITH N1AH / G2FD
H2RC018S06
N1AHB0806
2,5,8,10
17
G2FD024(S,H)17
600
19.6
13.2
12.50
12.50
11.60
H2RC024S06
N1AHB0806
2,5,8,10
17
G2FD024(S,H)17
750
23.6
16.9
12.00
12.00
11.00
N1AHB0806
2,5,8,10
17
G2FD030(S,H)17
750
24.0
17.3
12.00
12.00
11.10
H2RC030S06
N1AHB1206
2,5,8,10
17
G2FD030(S,H)17
1000
30.0
21.3
12.00
12.00
11.00
N1AHB1206
2,5,8,10
17
G2FD036(S,H)17
1000
30.6
21.8
12.25
12.25
11.20
H2RC036S06
N1AHB1206
5,8,10,15,19
17
G2FD036(S,H)17
1200
33.8
23.6
11.50
11.50
10.70
N1AHB1206
5,8,10,15,19
17
G2FD046(S,H)17
1200
35.0
24.4
12.00
12.00
10.90
H2RC042S06
N1AHC1606
5,8,10,15,20
21
G2FD042(S,H)21
1400
41.0
29.3
12.00
–
10.50
N1AHC1606
5,8,10,15,20
21
G2FD048(S,H)21
1400
42.5
30.6
12.00
–
10.75
H2RC048S06
N1AHC1606
5,8,10,15,20
21
G2FD048(S,H)21
1575
46.5
36.0
12.20
12.20
10.90
N1AHD2006
8,10,15,20,25,30
24
G2FD060(S,H)24
1575
48.0
36.4
12.50
12.50
11.10
N1AHD2006
8,10,15,20,25,30
24
G2FD061H24
1575
48.5
34.5
12.50
12.50
11.20
H3RC060S06
N1AHD2006
8,10,15,20,25,30
24
G2FD060(S,H)24
1800
57.5
42.6
–
12.00
10.40
N1AHD2006
8,10,15,20,25,30
24
G2FD061H24
1850
58.0
43.2
–
12.00
10.45
3 PH 12 SEER AC WITH N1AH / G2FD
H1RC036S(25,46)
N1AHB1246
5,8,10,15,18
17
G2FD036(S,H)17
1255
33.6
24.9
–
12.00
10.65
N1AHB1246
5,8,10,15,18
17
G2FD046(S,H)17
1250
34.8
25.8
–
12.00
10.95
N1AHC1646
5,8,10,15,18
21
G2FD048(S,H)21
1600
45.5
33.7
–
12.20
11.20
H1RC048S(25,46)
N1AHD2046
8,10,15,20,25,30
24
G2FD060(S,H)24
1620
47.0
34.8
–
12.50
11.45
N1AHD2046
8,10,15,20,25,30
24
G2FD061H24
1600
47.5
35.2
–
12.50
11.50
H1RC060S(25,46)
N1AHD2046
8,10,15,20,25,30
24
G2FD060(S,H)24(T)
1800
56.5
43.4
–
12.00
10.10
N1AHD2046
8,10,15,20,25,30
24
G2FD061H24
1800
56.5
43.8
–
12.00
10.15
1 PH 12 SEER / N1VS - VARIABLE SPEED
H2RC018S06
N1VSB12
10,15,18
17
G2FD024(S,H)17
650
20.2
13.2
13.75
13.75
12.80
H2RC024S06
N1VSB12
10,15,18
17
G2FD024(S,H)17
725
24.2
16.9
13.35
13.35
12.15
N1VSB12
10,15,18
17
G2FD036(S,H)17
775
25.2
17.8
13.50
13.50
12.50
H2RC030S06
N1VSB12
10,15,18
17
G2FD036(S,H)17
1000
31.0
21.9
13.25
13.25
12.15
N1VSB12
10,15,18
17
G2FD046(S,H)17
1000
32.0
22.3
13.75
13.75
12.55
N1VSB12
10,15,18
17
G2FD046(S,H)17
1000
32.0
22.3
13.75
13.75
12.55
H2RC036S06
N1VSB12
10,15,18
17
G2FD036(S,H)17
1200
34.8
23.6
12.40
12.40
11.35
N1VSB12
10,15,18
17
G2FD046(S,H)17
1210
35.8
24.4
13.00
13.00
11.65
N1VSC16
10,15,18
21
G2FD048(S,H)21
1155
36.8
25.1
13.40
13.40
12.20
H2RC042S06
N1VSC16
10,15,18
21
G2FD048(S,H)21
1400
43.0
30.6
13.00
–
11.55
N1VSC16
10,15,18
21
G2FD048(S,H)21
1590
47.0
30.6
12.80
–
11.40
H2RC048S06
N1VSC16
10,15,18
21
G2FD048(S,H)21
1590
47.0
34.9
12.80
12.80
11.40
N1VSD20
10,15,18,30
24
G2FD060(S,H)24
1560
48.5
36.0
13.25
13.25
11.75
N1VSD20
10,15,18,30
24
G2FD061H24
1560
49.0
36.4
13.30
13.30
11.90
H3RC060S06
N1VSD20
10,15,18,30
24
G2FD060(S,H)24
1780
56.0
42.3
–
12.10
10.25
N1VSD20
10,15,18,30
24
G2FD061H24
1780
56.5
42.7
–
12.25
10.40
1 PH 12 SEER AC / F2RP / RC / FC
4
,
5
H2RC018S06
F2RC/F2FC024
5,8,10
18
–
600
20.0
13.2
12.50
12.50
11.70
F2RP/F2FP024
5,8,10
18
–
600
20.0
13.2
12.50
12.50
11.70
H2RC024S06
F2RC/F2FC024
5,8,10
18
–
750
23.4
17.5
11.50
11.50
10.85
F2RC/F2FC030
5,8,10,15
18
–
750
23.4
17.5
11.50
11.50
10.85
F2RP/F2FP024
5,8,10
18
–
750
23.6
17.5
12.00
12.00
10.90
F2RP/F2FP030
5,8,10,15
18
–
750
24.0
17.9
12.00
12.00
11.10
H2RC030S06
F2RC/F2FC030
5,8,10,15
18
–
1000
29.8
21.5
12.00
12.00
11.00
F2RC/F2FC036
5,8,10,15
21
–
1000
31.0
22.4
12.25
12.25
11.30
F2RP/F2FP030
5,8,10,15
18
–
1000
30.2
22.9
12.00
12.00
11.15
F2RP/F2FP036
5,8,10,15,19
21
–
1000
30.2
23.5
12.00
12.00
11.15
H2RC036S06
F2RC/F2FC036
5,8,10,15
21
–
1200
34.6
26.2
12.00
12.00
10.85
F2RP/F2FP036
5,8,10,15,19
21
–
1200
34.6
26.2
12.00
12.00
10.85
F2RP/F2FP042
5,8,10,15
21
–
1200
34.8
26.3
11.60
11.60
10.70
F2FP048
5,8,10,15,20,25
24
–
1200
35.4
26.7
12.00
12.00
10.90
H2RC042S06
F2RP/F2FP042
5,8,10,15
21
–
1400
40.5
28.9
11.80
–
10.35
F2FP048
5,8,10,15,20,25
24
–
1400
42.5
30.5
12.00
–
10.55
H2RC048S06
F2FP048
5,8,10,15,20,25
24
–
1565
46.5
34.9
11.40
11.40
10.75
F2FP060
5,8,10,15,20,25
24
–
1575
48.0
35.9
11.50
11.50
10.70
F2FV060
8,10,15,20,25
24
–
1560
48.5
35.9
13.20
13.20
11.70
H3RC060S06
F2FP060
5,8,10,15,20,25
24
–
1800
56.0
42.0
–
12.00
10.00
F2FV060
8,10,15,20,25
24
–
1780
56.0
42.3
–
12.10
10.30
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8
0°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters. Three phase units require three phase 2HK heaters.
3. TXV = Thermal Expansion Valve kit required. Use 1TV700 series kit.
4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC
.
models. All ratings remain the same.
5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard.