York 12 SEER H*RC018 THRU 060 User Manual
Page 3
036-21137-004 Rev. C (0505)
Unitary Products Group
3
Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase
Outdoor Unit
H2RC018S06 H2RC024S06 H2RC030S06 H2RC036S06 H2RC042S06 H2RC048S06 H4RC060S06
Unit Orifice (s)
1
53
59
63
73
78
87
–
Factory R-22 Charge, lbs-oz.
4 - 9
4 - 7
5 - 8
5 - 3
6 - 13
7 - 7
8 - 15
Indoor Coil
5
Coil Orifice
4
Orifice or TXV Kit
2
- Additional Charge, Oz.
3
G2FD024(S,H)14,17
61
53 + 3
59 + 3
–
–
–
–
–
701 + 3
701 + 3
–
–
–
–
–
G2FD030(S,H)17
65
53 + 6
59 + 6
63 + 4
–
–
–
–
701 + 6
701 + 6
701 + 4
–
–
–
–
G2FD035(S,H)14
65
53 + 6
59 + 6
63 + 4
73 + 0
–
–
–
701 + 6
701 + 6
701 + 4
702 + 0
–
–
–
G2FD036(S,H)17
75
–
59 + 10
63 + 8
73 + 6
–
–
–
–
701 + 10
701 + 8
702 + 6
–
–
–
G2FD036(S,H)21
75
–
–
63 + 11
73 + 8
–
–
–
–
–
701 + 11
702 + 8
–
–
–
G2FD042(S,H)21
78
–
–
63 + 14
73 + 12
78 + 0
–
–
–
–
701 + 14
702 + 12
702 + 0
–
–
G2FD046(S,H)17
78
–
–
63 + 16
73 + 12
78 + 0
87 + 0
–
–
–
701 + 16
702 + 12
702 + 0
703 + 0
–
G2FD048(S,H)21,24
84
–
–
–
73 + 16
78 + 10
87 + 11
–
–
–
–
702 + 16
702 + 10
703 + 11
–
G2FD060(S,H)24
90
–
–
–
–
–
87 + 15
–
–
–
–
–
–
703 + 15
703 + 5
G2FD061H24
90
–
–
–
–
–
87 + 19
–
–
–
–
–
–
703 + 19
703 + 11
G1HA024H14
61
053 + 03
059 + 03
–
–
–
–
–
G1HA024H14(T)
TXV 701
+ 03
+ 03
–
–
–
–
–
G1HA036H14
75
–
59 + 12
63 + 11
73 + 08
–
–
–
G1HA036H14(T)
TXV 702
–
–
+ 11
+ 08
–
–
–
G1HA036H17
78
–
–
63 + 14
73 + 12
–
–
–
G1HA036H17(T)
TXV 702
–
–
+ 14
+ 12
–
–
–
G1HA048H21
84
–
–
–
73 + 09
78 + 07
87 + 08
G1HA048H21(T)
TXV 703
–
–
–
+ 09
+ 07
+ 08
G1HA060H24
90
–
–
–
–
–
87 + 15
G1HA060H24(T)
TXV 703
–
–
–
–
–
87 + 15
703 + 5
G1HD024
59
53 + 5
59 + 4
–
–
–
–
–
701 + 5
701 + 4
–
–
–
–
–
G1HD036
69
–
59 + 13
63 + 11
73 + 7
–
–
–
–
701 + 13
701 + 11
702 + 7
–
–
–
G1HD048
81
–
–
–
73 + 13
78 + 3
87 + 4
–
–
–
–
702 + 13
702 + 3
703 + 4
–
G1HD060
93
–
–
–
–
–
87 + 12
–
–
–
–
–
–
703 + 12
703 + 0
G1FA/G1UA024S14,17(T)
59
53 + 0
59 + 0
–
–
–
–
–
701
5
+ 0
701 + 0
–
–
–
–
G1FA/G1UA030S14(T)
65
–
59 + 3
63 + 0
–
–
–
–
–
701 + 3
701 + 0
–
–
–
–
G1FA/G1UA036S14(T)
73
–
59 + 8
63 + 6
73 + 3
–
–
–
–
701 + 8
701 + 6
702 + 3
–
–
–
G1FA/G1UA036S17,21(T)
73
–
59 + 6
63 + 4
73 + 0
–
–
–
–
701 + 6
701 + 4
702 + 0
–
–
–
G1FA/G1UA048S17(T)
84
–
–
63 + 16
73 + 13
78 + 0
87 + 0
–
–
–
701 + 16
702 + 13
702 + 0
703 + 0
–
G1FA/G1UA048S21(T)
84
–
–
63 + 18
73 + 9
78 + 7
87 + 8
–
–
–
701 + 18
702 + 9
702 + 7
703 + 8
–
G1FA/G1UA060S21,24(T)
90
–
–
–
–
78 + 16
87 + 15
–
–
–
–
–
702 + 16
703 + 15
703 + 5
G1NA030S17K
63
53 + 6
59 + 6
63 + 4
–
–
–
–
701 + 6
701 + 6
701 + 4
–
–
–
–
G1NA030S21M
78
53 + 6
59 + 6
63 + 4
–
–
–
–
701 + 6
701 + 6
701 + 4
–
–
–
–
See notes on Page 4.