beautypg.com

York 13 SEER - R410A CZB018 THRU 060 User Manual

Page 6

background image

246723-YTG-J-1006

6

Unitary Products Group

1 PH 13 SEER AC WITH AHP/ SHP / F*FP

CZB01811

AHP18

2,5,8

17

600

18.0

12.1

13.00

11.00

AHP24

2,5,8,10

17

600

18.0

12.3

13.00

11.00

F*FP024

5,8,10

17

600

18.0

12.1

13.00

11.00

CZB02411

AHP24

2,5,8,10

17

800

23.0

16.9

13.00

11.00

F*FP030

5,8,10,15

17

800

23.0

16.7

13.00

11.00

CZB03011

AHP30

5,8,10

17

1000

30.0

21.9

13.00

11.00

AHP36

5,8,10,15,18

17

1000

30.0

21.9

13.00

11.00

F*FP030

5,8,10,15

17

1000

29.6

21.6

13.00

11.00

F*FP036

5,8,10,15,19

21

1000

30.0

22.3

13.00

11.00

CZB03611

AHP36

5,8,10,15,18

17

1200

36.0

26.5

13.00

11.00

AHP42

5,8,10,15,18

21

1200

36.0

26.5

13.00

11.00

F*FP036

5,8,10,15,19

21

1200

36.0

26.7

13.00

11.00

F*FP042

5,8,10,15,18

21

1200

36.0

26.8

13.00

11.00

CZB04211

AHP/SHP48

5,8,10,15,20

24

1400

41.5

30.5

13.00

11.00

AHP/SHP60

5,8,10,15,20,25

24

1400

41.5

30.5

13.00

11.00

F*FP045

5,8,10,15

24

1400

41.0

30.2

13.00

11.00

F*FP048

5,8,10,15

24

1400

41.0

30.2

13.00

11.00

CZB04811

AHP/SHP48

5,8,10,15,20

24

1600

48.0

36.1

13.00

11.00

AHP/SHP60

5,8,10,15,20,25

24

1600

48.0

36.1

13.00

11.00

CZB06011

AHP/SHP60

5,8,10,15,20,25

24

1800

55.5

39.7

13.00

11.00

1 PH 13 SEER AC WITH AV / SV / F*FV VARIABLE SPEED

CZB01811

AV24

2,5,8,10

17

600

18.0

12.1

14.00

11.50

CZB02411

AV24

2,5,8,10

17

800

23.0

16.7

14.00

11.50

CZB03011

AV36

5,8,10,15,18

17

1000

30.0

21.9

14.00

11.50

CZB03611

AV36

5,8,10,15,18

17

1200

36.0

26.5

14.00

11.50

CZB04211

AV/SV48

5,8,10,15,20

24

1400

41.5

30.5

14.00

11.50

CZB04811

AV/SV48

5,8,10,15,20

24

1600

48.0

35.8

14.00

11.50

AV/SV60

5,8,10,15,20,25

24

1600

48.0

35.8

14.00

11.50

F*FV060

5,8,10,15,20,25

24

1600

48.0

36.5

13.25

11.00

CZB06011

AV/SV60

5,8,10,15,20,25

24

1800

57.0

40.8

14.00

11.50

F*FV060

5,8,10,15,20,25

24

1780

55.5

40.8

13.25

11.00

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8

0°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.

1

MC & G*FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.

2

Single phase units require single phase 2HK or 4HK heaters.

COOLING CAPACITY - With Air Handler Coils (Continued)

UNIT

MODEL

AIR HANDLER

COIL MODEL

1

COOLING

MODEL

ELECTRIC
HEAT KW

2

W

RATED

CFM

NET MBH

SEER

EER

TOTAL

SENS.