* Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one.
**

Refer to Quick Selection Chart for specific furnace match-up.

ACCESSORIES*

Enhanced Coil Guard - An enhanced coil guard which offers
superior protection from hail and other types of damage is
available.
* For the most current accessory information, refer to the
price book or consult factory.

SOUND RATINGS*

*Rated in accordance with ARI Standard 270.

COOLING CAPACITY -With Air Handler Coils

UNIT

MODEL

VAR SPEED AIR HANDLER

COIL MODEL

COOLING

MODEL

ELEC. HEAT

KW

W

STAGE

(# CYL)

RATED

CFM

NET MBH

SEER

EER

TOTAL

SENS.

H4TS024

N+VSB12

5,7.5,10,15,18

17

G2FD024S17

1

600

12.4

10.0

14.8

13.5

2

820

24.0

16.8

12.0

G2FD030S17

1

600

12.8

10.2

15.4

14.0

2

820

24.6

17.2

12.5

G2FD036S17

1

600

13.0

10.4

15.5

14.3

2

820

25.0

17.5

12.5

H4TS030

N-VSB12

5,7.5,10,15,18

17

G2FD030S17

1

670

15.0

12.0

14.0

12.7

2

1035

30.0

21.6

11.0

G2FD036S17

1

670

15.4

12.2

14.5

13.1

2

1035

31.0

22.0

11.0

N-VSC16

5,7.5,10,15,20

21

G2FD042S21

1

690

16.4

13.4

15.3

14.1

2

1065

31.6

23.4

11.2

H4TS036

N-VSC16

5,7.5,10,15,20

21

G2FD036S21

1

770

20.0

16.0

15.0

13.7

2

1185

35.0

26.0

11.3

G2FD042S21

1

770

20.0

16.0

15.0

13.7

2

1185

35.0

26.0

11.3

G2FD048S21

1

770

20.6

16.6

16.0

14.4

2

1185

36.0

26.6

12.5

H4TS048

N-VSC16

5, 7.5,10,15,20

21

G2FD048S21

1

1050

25.0

20.0

15.2

14.1

2

1605

47.5

35.0

10.4

N-VSD20

5, 7.5,10,15,20

24

G2FD048S24

1

1050

25.0

20.0

15.3

14.2

2

1570

47.5

35.0

10.5

G2FD060S24

1

1050

25.0

21.0

15.5

14.0

2

1570

49.5

37.0

10.7

H4TS060

N-VSD20

5, 7.5,10,15,20

24

G2FD060S24

1

1250

33.0

26.4

14.5

13.5

2

1900

59.0

43.0

10.4

G2FD061H24

1

1250

33.0

26.4

15.0

14.0

2

1900

59.5

44.0

10.7

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.

KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.

UNIT MODEL

SOUND RATINGS

DECIBELS

1 CYLINDER

2 CYLINDER

024

70 db

72 db

030

72 db

74 db

036

73 db

74 db

048

76 db

78 db

060

78 db

79 db