beautypg.com

York H4TS024 User Manual

Listed, Technical guide, Description

background image

TECHNICAL GUIDE

STEALTH

SPLIT-SYSTEM AIR CONDITIONERS

15 + SEER

MODELS:

H4TS024 THRU 060
(2 THRU 5 NOMINAL TONS)

Due to continuous product improvement, specifications
are subject to change without notice.

Visit us on the web at www.york.com for the most
up-to-date technical information.

Additional rating information can be found at
www.ariprimenet.org.

R

N

E

M

P

I

U

Q

E

T

Y

R

AT

I

N

U

0

1

2

A R

I

R

A

D

N

A

T

S

D

I

S

N

O

T

C

E

S

F

O

C

C

I

F

I

T

R

E

N

O

I

T

A

HT

I

W

C

G N

I

YL

P

M

O

S

A

I

R

A

O

T

D

E

I

F

I

T

R

E

C

R

E

R

UT

C

A

F

U

N

A

M

C

-

G

NI

N O

I

TI

D

N

O

R

I

A

CERTIFICATION APPLIES ONLY

WHEN THE COMPLETE

SYSTEM IS LISTED

WITH ARI.

LISTED

036-21023-005 Rev. A (0802)

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

The HTS Stealth series condensing units use Twin Single

compressor technology to provide cooling efficiencies up to
15.5 SEER. They are to be installed with the matching vari-
able speed enhanced Air Handler or Diamond Furnace, or
with a two-stage or single-stage indoor unit, a corresponding
coil and sweat connect lines. A factory specified balanced
port hard shut-off TXV kit must be used for proper installation
and optimum performance.

WARRANTY

5-year limited parts warranty.
10-year limited compressor warranty.

FEATURES

QUALITY CONDENSER COILS - The coil is constructed of

copper tube and hardened aluminum fins for durability and

long lasting efficient operation. The fins on the unit are pro-

tected with a decorative grille.

DURABLE FINISH - Cabinet is made of powder painted steel

over pre-primered steel. The pre-treated galvanized steel pro-

vides a better paint to steel bond, which resists corrosion and

rust creep. Special primer formulas and automotive quality fin-

ish insure less fading when exposed to sunlight.

PROTECTED COMPRESSORS - The Twin Single

 com-

pressor is protected against high and low pressure. Hard start

components are included to ensure start-up under adverse

conditions. All models have standard crankcase heat for

added protection.

OPTIMUM PERFORMANCE - The solid-state electronic con-

trolboard optimizes the compressor staging based on load

requirements, provides a 5-minute anti-short cycle timer for

the compressor, and simplifies troubleshooting with built in

self diagnostics.

LOWER INSTALLED COST - Installation time and costs are

reduced by easy power and control wiring connections. All

units contain enough refrigerant for the smallest matching

indoor coil and 15 feet of interconnecting piping. The small

base dimension means less space is required on the ground

or roof.

EFFECTIVE HUMIDITY CONTROL - The inherent design of

the Stealth system and the staging operation of the Twin Sin-

gle

 compressor provide effective humidity control at the low-

est possible operating cost. An optional dehumidification

control accessory is available to maintain the humidity at a set

desired level.

TOP DISCHARGE - The warm air from the top mounted fan is

blown up away from the structure and any landscaping. This

allows compact location on multi-unit applications.

LOW OPERATING SOUND LEVEL - The upward air flow car-

ries the normal operating noise up away from the living area.

The rigid top panel effectively isolates any motor sound. Isola-

tor mounted compressor and the rippled fins of the condenser

coil muffle the normal fan motor and compressor operating

sounds.

LOW MAINTENANCE - Long life permanently lubricated

motor- bearings need no annual servicing.

EASY SERVICE ACCESS - Fully exposed refrigerant con-

nections and a single panel covering the electrical controls

make servicing easy. Easy access for coil cleaning is also pro-

vided.

RE-USABLE SERVICE VALVES - Provided on both the liquid

and vapor sweat connections for ease of evacuating and

charging.

Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.