beautypg.com

York H4TS024 User Manual

Page 14

background image

036-21023-005 Rev. A (0802)

14

Unitary Products Group

Multipliers for determining the performance with other indoor sections.

COOLING PERFORMANCE DATA -

LOW CFM 1-CYLINDER OPERATION

AIR CONDITIONER MODEL NO.

H4TS060S06

INDOOR COIL MODEL NO.

G2FD061H24+N1VSD20

CONDENSER

ENTERING AIR

TEMPERATURE

ID CFM

1100

1200

1300

ID DB (°F)

85

80

75

70

85

80

75

70

85

80

75

70

ID WB (°F)

72

67

62

57

72

67

62

57

72

67

62

57

75

T.C.

39.8

36.4

33.1

30.0

40.1

36.8

33.5

30.4

40.5

37.2

33.8

30.9

S.C.

26.6

26.6

26.9

26.8

27.8

27.9

28.1

28.1

29.1

29.1

29.3

29.3

K.W

1.94

1.94

1.95

1.94

1.97

1.97

1.98

1.97

2.00

2.01

2.01

2.01

85

T.C.

37.8

34.5

31.4

28.4

38.1

34.9

31.8

28.9

38.3

35.2

32.1

29.4

S.C.

25.9

25.8

26.2

26.1

27.1

27.2

27.4

27.3

28.3

28.3

28.5

28.5

K.W

2.15

2.22

2.12

2.10

2.19

2.18

2.16

2.15

2.21

2.21

2.19

2.17

95

T.C.

35.7

32.6

29.7

26.9

35.9

33.0

30.0

27.5

36.3

33.3

30.2

28.0

S.C.

25.2

25.2

25.4

25.3

26.4

26.4

26.6

26.6

27.7

27.6

27.8

27.1

K.W

2.35

2.32

2.29

2.26

2.39

2.36

2.33

2.30

2.42

2.39

2.36

2.33

105

T.C.

33.5

30.7

27.9

25.4

33.9

31.0

28.1

25.9

34.1

31.2

28.5

26.4

S.C.

24.4

24.4

24.6

24.6

25.7

25.6

25.8

25.1

26.9

26.8

27.0

25.5

K.W

2.53

2.50

2.45

2.40

2.57

2.53

2.49

2.45

2.61

2.57

2.52

2.49

115

T.C.

31.4

28.7

26.0

23.9

31.7

28.9

26.4

24.4

31.9

29.1

26.8

24.8

S.C.

23.8

23.7

23.8

23.1

25.0

24.8

25.0

23.6

26.1

26.0

26.0

24.0

K.W

2.71

2.66

2.59

2.54

2.75

2.70

2.64

2.59

2.79

2.74

2.68

2.63

125

T.C.

29.3

26.7

24.1

22.4

29.5

26.8

24.7

22.9

29.7

27.0

25.1

23.2

S.C.

23.2

23.0

23.0

21.6

24.3

24.0

24.2

22.1

25.3

25.2

25.0

22.5

K.W

2.89

2.82

2.74

2.68

2.93

2.87

2.80

2.74

2.97

2.91

2.83

2.78

NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Air Handler

Coil

T.C.

S.C.

KW

N1VSD20

G2FD060S24

1.00

1.00

1.07

F2FV060

1.00

1.00

1.07

F2RP/F2FP060

0.97

1.00

0.96

G1HD060

0.97

1.00

1.13

G1FA060S21,24

0.97

1.00

1.13

G2FD060S24

0.97

1.00

1.13

G1UA060S21,24

0.97

1.00

1.13

Variable Speed

Furnace

Coil

T.C.

S.C.

KW

P1DUC20V096

G1FA060S21

1.00

1.00

1.11

P1DUC20V096

G1UA060S21

1.00

1.00

1.11

P1XUC20V095

G1FA060S21

1.00

1.00

1.12

P1XUC20V095

G1UA060S21

1.00

1.00

1.12

P1XUD20V112

G1FA060S24

1.00

1.00

1.07

P1XUD20V112

G1UA060S24

1.00

1.00

1.07

P1XUD20V112

G2FD060S24

1.00

1.00

1.07

P1XUD20V112

G2FD061H24

1.03

1.02

1.11