Parallel data port, Parallel port interconnections – Zebra Technologies XiIII Series User Manual
Page 105
![background image](/manuals/228126/105/background.png)
Zebra XiIII-Series User’s Guide
97
3DUDOOHO 'DWD 3RUW
A standard 36-pin parallel connector is available at the rear of the printer
for connection to the data source. Under normal circumstances, data sent
from the printer to the host computer in response to a “Printer Status
Request” command is sent through the RS-232 serial port. However, if the
host computer has a properly configured IEEE-1284 parallel port that is
recognized by the printer, status information is returned through the
parallel port. Port selection for status information is determined each time
the printer is turned on.
Parallel Port Interconnections
The following table shows the pin configuration and function of a standard
computer-to-printer parallel cable.
36-pin Connector
Description
1
nStrobe/HostClk
2-9
Data Bits 1-8
10
nACK/PtrClk
11
Busy/PtrBusy
12
PError/ACKDataReq
13
Select/Xflag
14
nAutoFd/HostBusy
15
Not used
16 & 17
Ground
18
+5V @ 1A
19-30
Ground
31
ninit
32
nFault/NDataAvail
33 & 34
Not used
35
+5V through a 4.7 KW Resistor
36
NSelectin/1284 active