Utility Displays

DME64N/DME24N Owner’s Manual

54

Check Page

Even in an environment with no computer, you can check
the connections without using DME Designer by directly
connecting the DME64N/24N input/output.
The meter does not operate during a connection check.

MODE: OFF

Makes connections in the configuration used in the
current scene.
This is set to OFF when the unit is started.

MODE: Thru

Directly connects the Input and Output of each slot one-
to-one for each channel.
When input-only or output-only cards like AD or DA
cards are inserted in the slots, you cannot perform
checks in this mode.
In the DME24N, the internal AD and internal DA are
directly connected on each channel.

MODE: Summing

Sums all input signals coming from Inputs (-12dB),
without regard to device or card type, and outputs it
through all Outputs.

NOTE

Make sure that the Mixer I/O setting is the same for all
cascaded DME64N/24N units.

NOTE

This page will not appear on the ICP1 display.