P

anel Oper

ation and Displa

y

s

Utility Displays

DME64N/DME24N Owner’s Manual

49

Int HA Ctrl (Internal head amp control)

Displays/sets the connector to be used for internal head
amp control. From a single digital mixer, you can control
the internal head amps of multiple DME series units
within the device group. Set this parameter only on the
DME series units that is connected directly to the digital
mixer, and turn in “OFF” for other units. Edit using the
“List Parameters” editing procedure described on page
38.

OFF:

Select “OFF” when this function is not to be

used.

Remote (422):

Allows a digital mixer to control the

internal head amps via RS-422 protocol.

Slot1 [Slot1 ~ Slot4 (DME64N)]:

Allows a digital

mixer to control the internal head amps via the
specified expansion slot.

Ext HA Ctrl (External head amp control)

Displays/sets the type of connection to be used for
external head amp control.

OFF:

Select “OFF” when this function is not to be

used.

Remote (422):

Allows remote head amp control.

Always use this setting when a remote head amp
unit (AD8HR, AD824) is connected. Also, don’t
change the setting while a remote head amp is
connected. Doing so can damage the unit.

COM

Displays/sets the type of connection to be used for DME
protocol communication. This is a Yamaha maintenance
function. Normally, set this to “OFF”.

MIDI Setup (MIDI) Page

Port (MIDI port)

Sets/displays the port to be used for MIDI
communication. The available settings are: OFF,
Remote(232C), Remote(422), MIDI, USB-1, USB-2,
SLOT-1, SLOT-2, SLOT-3, and SLOT-4.

OFF:

Select

OFF

when this function is not to be

used.

Remote (232C):

MIDI data will be received via the

[REMOTE] connector using an RS-232C
connection.

Remote (422):

MIDI data will be received via the

[REMOTE] connector using an RS-422 connection.

MIDI:

The MIDI connector is the currently active

MIDI port.

USB-1, USB-2:

The corresponding USB port is

selected for MIDI input.

Slot1 [Slot1 ~ Slot4 (DME64N)]:

A card installed

in the corresponding I/O slot is currently selected
for MIDI input.

Edit using the “List Parameters” editing procedure
described on page 38.

NOTE

This page will not appear on the ICP1 display.

NOTE

When the DME64N/24N is functioning as the device
group master and is connected to a computer running
the DME Designer application via USB, the MIDI port