Utility Displays

DME64N/DME24N Owner’s Manual

47

LCD Backlight

Specifies LCD backlight operation. Two settings are
available: “ON,” and “OFF.”

ON:

The display is continuously lit.

OFF:

The display lights when a control is operated,

and will go out 10 seconds after panel operation
ceases.

Pressing the [ENTER] button alternately selects “ON”
and “OFF”.

Meter Fall Time

Determines the fall time of the level meters – “Fast” or
“Slow.”

Fast:

The meters rapidly follow changes in the

signal level.

Slow:

The meters fall slower than the actual

changes in the signal level, allowing easier reading
in some cases.

Edit using the “List Parameters” editing procedure
described on page 38.

Security Setup (Lock) Page

Panel lock and related settings.

Utility

The lock status for the Utility display settings. This
parameter can be set to “Unlock” or “Lock.”

Unlock:

The Utility display can be accessed

without a password.

Lock:

A password must be entered to access the

Utility display.

When “Lock” is selected a password entry window will
appear when the [UTILITY] button is pressed to access
the utility pages.

Use the [ E ] and [ F ] buttons to position the cursor,
and the dial to enter the desired character at the cursor
location. When all of the password’s characters have
been entered as required press the [ENTER] button.

The password will also be required when switching from
the “Unlock” mode to the “Lock” mode.

Panel Lock Boot

Determines whether or not panel lock will be on when
power to the device is turned on. This parameter can be
set to “Unlock” or “Lock.”

Unlock:

Panel lock is OFF when power to the

device is turned on.

Lock:

Panel lock is ON when power to the device is

turned on.

Panel Lock Target

Determines the controls (control functions) to be affected
by panel lock. The available settings are “Key Only” and
“Key+GPI.”

Key Only:

Panel lock only affects the panel

buttons.

Key+GPI:

Panel lock applies to the panel buttons

as well as GPI control input.

User Defined Lock

Sets the lock status individually for each of the four User
Defined Button pages.

ON:

The corresponding User Defined Button will

not appear on the display.

OFF:

The corresponding User Defined Button will

appear on the display.

To change the settings use the [ E ] and [ F ] buttons to
move the cursor to the setting for the desired page, the
press the [ENTER] button to alternately turn the setting
“ON” and “OFF.”

NOTE

Password security and management is very important!
If you forget your password the unit cannot be operated!
If you forget your password contact the system
administrator.
If the password become unrecoverable for some reason
and you need to unlock the system, please contact your
Yamaha representative.

NOTE

See page 36 for details on how to use the Panel lock
feature.

NOTE

This parameter is displayed, but cannot be changed on
the ICP1 display.

NOTE

The User Defined Button are accessed as described in
the “Parameter Edit Display” section on page 36.