TABLE 16: ELECTRICAL DATA DH120 (10 TON) HIGH EFFICIENCY W/O PWRD CONVENIENCE OUTLET

TABLE 17: ELECTRICAL DATA DH120 (10 TON) HIGH EFFICIENCY WITH PWRD CONVENIENCE OUTLET

RLA

LRA

FLA

2

3

2

3

2

3

2

3

2

3

ea.

ea.

ea.

HP

HP

HP

HP

HP

HP

HP

HP

HP

HP

None

--

--

51.2

53.9

56.7

59.4

60

60

70

70

2TP04521825

13.5

37.5

57.1

60.5

64.0

67.3

60

70

70

70

2TP04522425

18

50.0

72.7

76.1

79.6

83.0

80

80

80

90

2TP04523625

25.5

70.8

98.7

102.1 105.6 109.0 100 110

110

110

2TP04525425 40.6

112.7

151.1

154.5 158.0 161.4 175 175

175

175

None

--

--

51.2

53.9

56.7

59.4

60

60

70

70

2TP04521825

18

43.3

64.4

67.8

71.3

74.6

70

70

80

80

2TP04522425

24

57.7

82.4

85.8

89.3

92.7

90

90

90

100

2TP04523625

34

81.8

112.5

115.9 119.4 122.7 125 125

125

125

2TP04525425

129.9

140.2

143.5 147.0 150.4 150 175

175

175

None

--

--

26

27.2 28.2 29.4 30 35

35

35

2TP04521846

18

22.6

32.2

33.7 34.9 36.4 35 35

35

40

2TP04522446

24

30.1

41.2

42.7

44

45.5 45 45

45

50

2TP04523646

34

42.7

56.2

57.7

59

60.5 60 60

60

70

2TP04525446

54

67.8

70.1

71.6 72.8 74.3 80 80

80

80

None

--

--

20.6

21.1 22.4 22.9 25 25

25

25

2TP04521858

18

18.1

26.2

26.8 28.4

29

30 30

30

30

2TP04522458

24

24.1

33.4

34

35.6 36.2 35 35

40

40

2TP04523658

34

34.1

45.4

46

47.6 48.3 50 50

50

50

2TP04525458

54

54.2

56.5

57.1

58.7 59.3 70 70

70

70

*

Pwr
Exh

Motor

Electric Heater

Model No.

Actual

KW

0.0

5.5

0.0

1.6

4.1

5.3

2.2

0.0

3.5

8.2

10.9

16.0

137.0

8.3

69.0

8.2

10.9

5.5

0.0

Maximum HACR breaker of the same AMP size is applicable.

6.4

58.0

1.3

3.6

4.1

1.8

MCA

w/Power

Exhaust

(Amps)

Max

Fuse*

Size

(Amps)

Max Fuse* Size

w/Power

Exhaust

(Amps)

FLA

Pwr

Conv

Outlet

Heater

Amps

Min. Circuit

Ampacity

(Amps)

FLA

208

16.0

137.0

3.5

230

460

575

Voltage

Compressors

OD Fan

Motors

Supply
Blower

Motor FLA

54

RLA

LRA

FLA

2

3

2

3

2

3

2

3

2

3

ea.

ea.

ea.

HP

HP

HP

HP

HP

HP

HP

HP

HP

HP

None

--

--

61.2

63.9

66.7

69.4

70

70

80

80

2TP04521825

13.5

37.5

69.6

73.0

76.5

79.8

70

80

80

80

2TP04522425

18

50.0

85.2

88.6

92.1

95.5

90

90

100

100

2TP04523625

25.5

70.8

111.2

114.6 118.1 121.5 125 125

125

125

2TP04525425 40.6

112.7

163.6

167.0 170.5 173.9 175 175

175

175

None

--

--

61.2

63.9

66.7

69.4

70

70

80

80

2TP04521825

18

43.3

76.9

80.3

83.8

87.1

80

90

90

90

2TP04522425

24

57.7

94.9

98.3

101.8 105.2 100 100

110

110

2TP04523625

34

81.8

125.0

128.4 131.9 135.2 125 150

150

150

2TP04525425

129.9

152.7

156.0 159.5 162.9 175 175

175

175

None

--

--

31

32.2 33.2 34.4 35 40

40

40

2TP04521846

18

22.6

38.4

39.9 41.2 42.7 40 40

45

45

2TP04522446

24

30.1

47.5

49

50.2 51.7 50 50

60

60

2TP04523646

34

42.7

62.5

64

65.2 66.7 70 70

70

70

2TP04525446

54

67.8

76.3

77.8 79.1 80.6 90 90

90

90

None

--

--

24.6

25.1 26.4 26.9 30 30

30

30

2TP04521858

18

18.1

31.2

31.8 33.4

34

35 35

35

35

2TP04522458

24

24.1

38.4

39

40.6 41.2 40 40

45

45

2TP04523658

34

34.1

50.4

51

52.6 53.3 60 60

60

60

2TP04525458

54

54.2

61.5

62.1

63.7 64.3 70 70

70

70

*

2.2

5.0

6.4

58.0

1.3

3.6

4.1

1.8

4.0

8.3

3.5

8.2

10.9

5.5

10.0

3.5

8.2

10.9

5.5

10.0

69.0

1.6

4.1

5.3

460

Maximum HACR breaker of the same AMP size is applicable.

575

Min. Circuit

Ampacity

(Amps)

MCA

w/Power

Exhaust

(Amps)

Max

Fuse*

Size

(Amps)

Max Fuse* Size

w/Power

Exhaust

(Amps)

Heater

Amps

FLA

208

230

Compressors

OD Fan

Motors

16.0

137.0

16.0

137.0

Voltage

Electric Heater

Model No.

Actual

KW

Supply
Blower

Motor FLA

Pwr
Exh

Motor

FLA

Pwr

Conv

Outlet

54

This manual is related to the following products: