Troubleshooting

Pairing was specified, but the signal phase

does not match.

• Even when channels are paired,

the phase setting is not linked.

................................ page 102

Automation (Automix) cannot be stopped.

• Has the REMOTE AUTOMATION SETUP

parameter been set to correctly?

............................... page 88

Can’t use the internal effects.

• Effect BYPASS may be turned ON.

........................ page 102

• Are the level of STEREO IN 1, 2 faders raised?

........ page 99

• EFFECT PATCH may be set to

insertion (each channel).

......................................... page 102

• It is not possible to insert one effect

into multiple channels.

........................................... page 102

• 019. HQ. Pitch can be used only with EFFECT 1.

• When the sampling rate is 96kHz/88.2kH, only Effect 1 can be

used.

Can’t use SOLO.

• The channel may be set to Solo Safe.

........................ page 96

Fader groups and mute groups don’t work.

• In the Fader Group page and Mute Group page,

check that grouping is set to ENABLE.

.................. page 101

The pitch is wrong.

• Is the 01X operating on the same sampling frequency

as the synchronized external device?

......... page 92, “Connecting a Computer to an mLAN

device via mLAN” (Installation Guide), “mLAN Con-
nection Settings” (Graphic Patchbay Online Manual)

• Is the master device operating in a stable way?

• Is an effect such as HQ.Pitch or

Dual Pitch selected?

............................................... page 102

The layer of 17-24 (mLAN9-16) cannot be

used.

• When the sampling rate is set to 96kHz/88.2kHz,

the layer of 17 – 24 (mLAN) can not be selected.

..... page 40

Cannot edit with Studio Manager.

• Has the STUDIO MANAGER ID

been set correctly?

.................................................... page 94

• Is Port 4 (Studio Manager) selected for

Studio Manager data transmission/reception?

.......................... Studio Manager Owner’s Manual (PDF)

The Remote Control or Automation

features do not work.

• Is the correct DAW software selected in Remote Select?

........ page 87, “Demo playback/Remote Control Setup”

(Installation Guide)

• Are the mLAN settings correct?

.........“Demo playback/Remote Control Setup”

(Installation Guide)

• Are settings on the DAW correct?

.........page 87, “Demo playback/Remote Control Setup”

(Installation Guide)

• Is Port 1 selected for mLAN MIDI transmission/reception?

.........page 87, “Demo playback/Remote Control Setup”

(Installation Guide)

Cannot change the wordclock.

• Set this with the mLAN Auto Connector or

Graphic Patchbay when using mLAN.

.........“Connecting a Computer to an mLAN device via

mLAN” (Installation Guide), “Wordclock Settings”
(Graphic Patchbay Online Manual)

• Is the mLAN Auto Wordclock (AUTO W.CLK)

setting appropriate?

.........“Connecting a Computer to an mLAN device via

mLAN” (Installation Guide)

The mLAN connection does not work.

• Has the driver been installed?

.................... Installation Guide

• Is the mLAN cable properly connected? Check the connec-

tion; disconnect the mLAN cable once, then insert it again.

• (For Windows) Is mLAN set to “ON”? From the taskbar,

right click on the mLAN Manager icon.

.........“Confirming the installation” (Installation Guide)

• (For Windows) When adding a new IEEE 1394 card, right click

on the mLAN Manager icon in the taskbar and select “ON.”.

.........“Confirming the installation” (Installation Guide)

• Is the ACTIVE lamp on the rear panel of the 01X lit (in blue)?

If it is not lit, check the followings:

• In mLAN Driver Setup (from taskbar, right click on the mLAN

Manager icon, then “Driver Setup”), is the Status indicator
blue? If not, restart the 01X and re-enable connection by using
mLAN Auto Connector or Graphic Patchbay.

.........“Confirming the installation” (Installation Guide),

Graphic Patchbay Online Manual

• Is mLAN AUTO W.CLK (Auto Wordclock)

on the 01X set to “ENABLE”?

.........“Connecting a Computer to an mLAN device via

mLAN” (Installation Guide)

• Has connection been enabled with mLAN

Auto Connector or Graphic Patchbay?
Re-enable connection if necessary.

.........“Connecting the Computer and mLAN devices via

mLAN” (Installation Guide), “mLAN Connection
Settings” (Graphic Patchbay Online Manual)

• Have you changed the device? Even if the model is the same,

if the actual device is different, it is necessary to re-enable con-
nection by using mLAN Auto Connector or Graphic Patchbay.

.........“Connecting the Computer and mLAN devices via

mLAN” (Installation Guide), “mLAN Connection
Settings” (Graphic Patchbay Online Manual)

• Is there a loop connection? Check the cabling and make sure

none of the devices are connected in a loop.

Computer

Computer

01X

01X

: IEEE 1394-equipped device

Example of loop connection