ADJUSTABLE HEATING AND COOLING

CYCLE TIMES (ANTICIPATION) — If the
heating/cooling system is turning on and off
too often (short cycles) or not often enough
(long cycles), you may want to adjust the
anticipation setting.

A cooling anticipation setting of less
than 10 may cause decreased compres-
sor life.

To adjust anticipation, press

SET

CLOCK

and

ADV
DAY

at the same time. The display will show
HEAT 5 (this is the factory preprogrammed
heating anticipation setting). You may se-
lect any anticipation setting from 4 to 40. If

the heat cycles are too short, press

TIME
FWD

to

HOLD TEMPERATURE — The thermostat

can hold any temperature within its range
for an indefinite period, without reverting to

the program. Press

HOLD

COPY

. HOLD will be

displayed. Then choose the desired hold
temperature by pressing

or

. The

thermostat will hold the room temperature

at the selected setting until you press

RUN

PRGM

to start program operation again. This fea-
ture is ideal for energy conservation when
the building is unoccupied for an extended
period of time.

°

F/

°

C CONVERTIBILITY — Press

TIME
FWD

and

TIME

BACK

at the same time until the tem-

perature display is in

°

C (Celsius). To dis-

play

°

F, repeat the process.