OPERATING FEATURES

Now that you are familiar with the thermostat
display and buttons, read the following informa-
tion to learn about the many features of the
thermostat.

COMPUTED ENERGY MANAGEMENT

RECOVERY (EMR) — The thermostat’s
microcomputer automatically calculates the
time it will take to change the temperature to
the next program setting. Then the thermo-
stat will activate the heating or cooling sys-
tem to change the temperature so that the
desired temperature is reached at the be-
ginning of the next program period. As an
example of this feature, assume that you
have programmed your thermostat to pro-
vide an overnight heating temperature of
62

°

F, and that during the next program

period, beginning at 6:00 AM, you have

programmed a temperature of 70

°

F. The

thermostat will automatically activate the
heating system at about 5:00 AM, so that
the programmed 70

°

F temperature is

reached by about 6:00 AM.

This feature is enabled by option switch #3.
To enable the EMR function, you must
move option switch #3 (located on the back
of the thermostat body) to the ON position.

To do this, press

SYSTEM

HEAT - OFF - COOL - AUTO

until OFF is dis-

played on the thermostat. Remove the ther-
mostat body from the wall, turn it over, and
check the position of option switch #3. If the
switch is ON (up), simply put the thermostat

back on the wall and press

SYSTEM

HEAT - OFF - COOL - AUTO

until the

desired operating mode is displayed. If the
switch is OFF (down), use a pencil or small
screwdriver to move the switch to the ON