beautypg.com

Wayne-Dalton TORQUEMASTER 3663-372 User Manual

Page 22

background image

15

Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need.

You can reach us Toll Free at 1-888-827-3667 for Consumer Assistance or online at www.wayne-dalton.com

Attaching Disconnect Handle

#6-20 x 1/2”

Screw

Disconnect

Handle

Bracket

Disconnect

Cable

Disconnect

Handle

Upper

Position

Apply emergency disconnect label next to
the mounted bracket. Use mechanical
fasteners if adhesive will not adhere.

Using the emergency disconnect, pull down
on disconnect handle and place it in the
manual door operated position (use
disconnect label for reference). Motor will
be rotated 90° from its packaged position.

If motor does not pivot 90°, see
troubleshooting section in this manual.

Disconnect Handle Usage

Emergency
Disconnect

Label

Manual operated position

Motor operated position

Tools Needed:

None

Tools Needed:

Phillips

Head

Screwdriver

Wire Cutters

Flat Blade

Screwdriver

NOTE:

The motor must be in the fully down

position before setting handle position on
cable. Bring motor to the down position by
pulling the disconnect cable while pushing
the motor down. Insure opener disconnect
teeth are engaged before installing
disconnect handle. If motor is not fully down
when teeth are engaged, turn motor shaft
with screwdriver at back of motor counter
clockwise until motor is fully down.

NOTE: Do not use power drill to assemble
set screw to handle.

Start the #6-20 x 1/2" screw into the
disconnect handle. Thread the disconnect
cable through the top of the disconnect
handle bracket and then the disconnect
handle.

Locate the disconnect handle in full upper
position of disconnect handle bracket.

Remove all disconnect cable slack between
the opener and the top of the disconnect
handle bracket. Tighten #6-20 x 1/2" screw
into the disconnect handle until snug, and
then tighten screw an additional 1 to 1-1/2
turns to secure disconnect cable to the
disconnect handle. Trim off excess cable
from bottom of the disconnect handle.

CAUTION:

PULL CABLE ONLY TAUT

ENOUGH TO REMOVE THE CABLE SLACK.
PULLING THE CABLE MORE COULD CAUSE
OPENER TO DISCONNECT FROM THE
TORQUE TUBE AND CAUSE FAILURE OF THE
DISCONNECT.

8

9