beautypg.com

Troubleshooting – Wayne-Dalton TORQUEMASTER 3663-372 User Manual

Page 48

background image

41

Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need.

You can reach us Toll Free at 1-888-827-3667 for Consumer Assistance or online at www.wayne-dalton.com

Troubleshooting

Symptom

Probable Cause

Corrective Action

Opener does not respond to the Wall Station or

Transmitter.

No power to the Opener.

Controls are not programmed.

Check the Opener Power Cord to outlet connection.

See Activation and Programming section.

Opener works from the Wall Station but not from the

Transmitter.

Transmitter is not programmed.

Weak or dead Transmitter battery.

See Activation and Programming section.

See Maintenance section for battery replacement.

Opener works from the Transmitter but not from the

Wall Station.

Wall Station is not programmed.

Weak or dead Wall Station battery.

See Activation and Programming section.

See Maintenance section for battery replacement.

Door does not move and the Opener beeps two times.

The profile routine has not been performed.

Perform the profile routine Step 24 or 25.

Door does not move with a Wall Station or Transmitter

command and no beeps come from the Opener.

Blown fuse or tripped circuit breaker.

No power to the Opener.

Reset the circuit breaker or contact a qualified service

person for fuse information.

Check Power Cord connection.

Door does not move with a Wall Station or Transmitter and

Opener beeps one time.

Possible loose Motor connection.

Check Motor plug connection.

Door stops or reverses, and the Opener beeps three or four

times.

Obstruction encountered.

Safety Sensor misalignment (if applicable).

Out-of-balance condition detected.

Clear the door path.

Re-align Safety Sensors Step 21.

Run new Profile Routine Step 24 or 25.

Door does not close properly.

Counterbalance Cables are not on the Cable Drums

properly.

Apply constant pressure to the Wall Station’s

Up/Down Button to close the door.

Door will not close.

Thermal delay: The door has cycled eight times

in a five-minute period.

Safety Sensor misalignment (if applicable).

Contact obstruction test failure.

Door will operate after a one-minute waiting period.

Re-align Safety Sensors Step 21.

Apply constant pressure to Wall Station Up/Down

Button until door is closed

Repeat the profile routine Step 24 or 25 or contact a quali-

fied service person.

Door does not travel to the full open or full close position.

Door is out of balance.

Door limits are set improperly.

Adjust the springs to correct the balance or call a qualified

service person.

Repeat the profile routine Step 24 or 25.

Door is not sealing to the floor.

Bottom door limit is set too high.

Outside door seal is set too tightly against the face of the

door.

Disconnect the Opener and force the door to the floor.

Reconnect the Opener and activate the profile routine Step

24 or 25.

Adjust weather seal position.

Motor does not pivot up fully when door is opening.

Counterbalance springs have too much tension.

Adjust the springs to correct the balance or call a qualified

service person.

Profile routine may have to be rerun. Step 24 or 25.

Door is reversing at or near the floor.

Outside door seal is too tight against the face

of the door.

Counterbalance springs have too much tension (torsion).

Vertical Track is spaced too close to the bottom door

section, causing the door to bind.

Reinstall the door seal so as to be not so tight against the

face of the door.

Adjust Track away from the door until binding is removed.

Contact a qualified service person.