Programming Steps 3 through 6
Now that you see how it’s done, enter the data for Set Point
Steps #3,4,5,
&
6. But,
be sure to stop and then return to these instructions when the display reaches “07
SP.” This is because you will be looping through Steps #4 through #6 three times.
Refer to the table below for
Steps #3,4,5
and
6.
FCTN
I
STEP #2
STEP#3
STEP #4
STEP#5
Step#6
Programming Step 7, a Jump Loop Step
You now
have Steps #1-6 programmed. When you run the program, Step #7
will be
performed when Step #6 is completed. But, you do not want Step #7 to be a normal
“Set Point Step.” We want Step # 7 to cause the 1500 to JUMP
back to
Step #4 two
times (for a total of 3 times through Steps #4-6). That’s why you’ll program Step #7 as
a"JUMP LOOP
Step.”
1.
With
the STEP and FUNCTION displays now reading “07 SP,” press the
FCTN key until “07 JL” comes up.
2.
3.
Press the ENTER key. The display changes to “JS” (Jump to Step #).
Enter the number of the step the program will jump to (“0004”). Press
ENTER. The display changes to “JC” (Jump Count).
4.
Since you want to jump back to Step #4 two times (total of 3 times through
the loop), enter “0002.” Press ENTER. The display changes to “07 NX 0008.”
5.
Press ENTER (you do want to program Step
now). The diiplay
changes to “08 SP.”
Programming Step 8
You’re ready to enter Step #8. It’s a normal Set Point Step, enter the information
below (Stop with the display reading “08 NX 0009”):
S1
110.0
S2 065.0
El
1100
E2
0101
HR
0000
MN
0006
SC
0000
Recall that you set the Recycle (RC) option to ON, so the program will repeat
indefinitely. You have now entered the entire program.
You’re almost ready to run it.
Table
3 -
Sample Program
Steps
CAUTION:
Notice on the
Sample Program
Chart (at the
beginning of this
section) that the
Series
1500
hoIds
the Step #8 set
points and Step
#8 Event Outputs
ON as lt recycles
and waits through
Step #1 before
beginning
the
program over.
Sample Program, Chapter 2
WATLOW Series 1500 Users
21