Outdoor—ventilation, Installation requirements, Built-in 18”h. wall hood – Viking OUTDOOR-COOKING VGBQ3002T1NSS User Manual
Page 65
Proper installation/ ducting is
extremely important to ensure
maximum performance. Use a qualified
and trained installer.
DUCTING
• Check with a qualified and
trained installer or local codes
for makeup air requirements, if
any.
• Max. duct run
o For 1,200 CFM—50’ (15.2 m)
o For 1,500 CFM—75’ (22.9 m)
o Duct run length is for
general reference only; for
longer duct runs, increase
duct size and contact a
qualified and trained
installer.
o The 1,500 CFM ventilator
should be used with longer
duct runs.
o Straight runs and gradual
turns are best; for example,
each 90° elbow is equivalent
to 5 – 10 feet (1.52 – 3.05
cm) of straight run.
• 10” duct run for 900 – 1500
CFM
o Never use flexible duct; it
creates back pressure/air
turbulence and greatly
reduces performance.
ELECTRICAL
• Hardwire direct with two-wire
with ground
• 120 VAC/60 Hz
PLUMBING
Not applicable
GAS
Not applicable
VWH4878T
48”W. Hood (for 41”W. grills)
VWH6078T
60”W. Hood (for 53”W. grills)
VWH3678T
36”W. Hood (for 30”W. grills)
P L A N N I N G A N D D E S I G N G U I D E
V I K I N G R A N G E . C O M • 1 - 8 8 8 - V I K I N G 1
R E L E A S E D 1 2 / 1 / 0 7
© 2 0 0 7 V R C — INFORMATION SUBJECT TO CHANGE
OUTDOOR—VENTILATION
Built-In 18”H. Wall Hood
UTILITY
REQUIREMENTS
Installation Requirements
Model
Ventilator Kits
Duct Size
Max. Amps*
Interior
Exterior
Interior
Exterior
Interior
Exterior
VWH3678T
VIV1200
VEV1200/1500
10” (25.4 cm)
10” (25.4 cm)
8.7
6.1/6.8
VWH4878T
VIV1200
VEV1200/1500
10” (25.4 cm)
10” (25.4 cm)
11.5
8.8/9.5
VWH6078T
VIV1200
VEV1200/1500
10” (25.4 cm)
10” (25.4 cm)
11.5
8.8/9.5
*Maximum amp rating for hoods includes recommended ventilator kit rating.