41 charcoal filter, 41 microwave, Oven light – Viking Built-In Convection Microwave Hood User Manual
Page 41: Charcoal filter, Microwave
41
4. Close light cover and secure with screw removed in step 2.
Cautions: Light cover may become very hot. Do not touch glass when light
is on. Do not use light for long time use such as a night light.
CHARCOAL FILTER
Charcoal Filter is used for Non-vented, recirculated installation. The filter
should be changed every 6 to 12 months depending on use.
1. Disconnect power to the oven at the circuit breaker panel or by unplugging.
2. Remove 2 screws that secure louver.
3. Remove louver by gently moving louver and pull away from unit.
4. Slide Charcoal Filter into position on support tabs.
5. Push louver back into place and replace the 2 screws to secure louver.
MICROWAVE
OVEN LIGHT
Remove the louver per instructions 1-3 above and charcoal filter, if used.
4. Slide the light cover forward and lift up.
5. Remove old light bulb and replace only with a 20 watt bulb available at
most hardware stores or lighting centers. DO NOT USE A BULB LARGER
THAN 30 WATTS.
6. Replace the microwave oven light cover and charcoal filter, if used; push
louver back in place and replace the louver mounting screws.
Louver
Oven light
Charcoal filter
Screw