Rs-232 controller connection, Figure 3-4 . rs-232 control system connection, 4. rs-232 control system connection – Vidikron VP-5000 User Manual
Page 29: Pre l iminar y

Vidikron PlasmaView Owner’s Operating Manual
19
PRE
L
IMINAR
Y
RS-232 Controller
Connection
Use a 9-pin, “null-modem” (cross-over) RS-232 cable to connect a PC or home theater
control/automation system (if present) to the EXTERNAL CONTROL port on the PlasmaView;
see Figure 3-4.
For more information about using this connection, refer to Serial Communications on
page 43.
Figure 3-4. RS-232 Control System Connection
2
3
8
5
XMT DATA
RCV DATA
REQUEST TO SEND*
* Short 7 and 8 together if the control system does not send RTS.
CLEAR TO SEND
SIG GND
2
3
7*
8*
5
RCV DATA
XMT DATA
CLEAR TO SEND*
NO CONNECTION
1, 9
1, 9
7
DATA TERMINAL READY
4
REQUEST TO SEND
4
6
6
DATA SET READY
SIG GND
DATA SET READY
DATA TERMINAL READY
To/From
PC or
Automation/
Control System
(DB-9 or other
connector type,
as required)
DB-9 Female
1
5
6
9