VBrick Systems VB5000 User Manual
Page 60

52
© 2009 VBrick Systems, Inc.
Figure 3. Script Management – Part 2
Run Scripts Using the IR Remote Control
IR Remote Control scripts are enabled by simply placing a file named
irNScript.txt
(where
N
is a number from 0–9) in the script directory of the unit. For example naming the following
script
ir0Script.txt
will enable the
0
on the IR remote to trigger the unit to run the script.
Run Scripts Using Event Triggers
The event triggering feature lets you use an external switch or power source to control the
functions of the VBrick appliance. See "Event Triggering" in the VBrick Appliance Getting
Started Guide for detailed examples.
Click here to read
or write script files
Login to the VBrick via FTP and manage script files. Requires a valid
user name and password.
Event Enable
Allows the user to Enable/Disable Event Triggering for each input
event.
Event Stable Time Allows the user to enter the amount of time in milliseconds that each
input event has to be stable at the active level before the script will be
executed.
Event Count
Displays the number of times each input event has occurred.
Event Script Status Displays current status information for each event script.
Run Script
These buttons allow the user to run each script without needing the
input event. Use this method to test the script.
IR Remote Scripts
are enabled by simply placing a file named
irNScript.txt
(where
N
is a
number from
0–9
) in the script directory of the unit. For example
naming the following script
ir0Script.txt
will enable the
0
on the IR
remote to trigger the unit to run the script.