beautypg.com

Wireless multiple flash shooting, D –42 – Nikon SB-900 User Manual

Page 92

background image

D–42

D

Flash modes and functions

Wireless multiple flash shooting

Confirming flash operation using the ready-light or sound monitor

Confirming shooting situations in wireless multiple

flash operation

You can confirm wireless multiple flash operation by checking the ready-light on
the SB-900 or the sound monitor during and after shooting.

When the SB-900 is used as a wireless remote flash unit, you can monitor its operation
by listening to the sound monitor. This function can be activated or canceled using
custom setting (kC-24). This function is set to activate as the default.
To save battery power, the ready-lights on the remote flash units can be turned
off in the custom setting. The rear ready-light is set to light up and the front
ready-light is set to blink as the default. (kC-24)

Ready-light of

master fl ash unit

Ready-light of

remote fl ash unit

Sound monitor

Speedlight condition

Lights up

The rear ready-
light lights up and
the front ready-
light blinks.

One beep

Ready to fi re

Lights up or does
not come on (not
blinking)

The rear ready-
light lights up,
and the front
ready-light blinks
or goes out.

Two short beeps

Fired properly

Blinks for approx.
3 sec.

Quickly blinks for
approx. 3 sec.

Three long beeps
for approx. 3 sec.

Both the master and remote fl ash units have
fi red at full output but light may have been
insuffi cient for correct exposure. Use a wider
aperture and reshoot.

Lights up or does
not come on (not
blinking)

Quickly blinks for
approx. 3 sec.

Three long beeps
for approx. 3 sec.

The light sensor of remote fl ash could not
receive correctly the command light from
master fl ash. The light sensor could not detect
when to stop fi ring in sync with the master
fl ash unit, because a strong refl ection from the
remote fl ash unit itself or light from another
remote fl ash unit may have entered the light
sensor window. Change the direction or
position of the remote fl ash unit and reshoot.

Normal operation

Normal operation

Warning chime rings
twice (when the
SB-900 detects high
temperature), or once
(for each fl ash fi ring)

The SB-900’s temperature has risen as
a result of the fl ash being fi red multiple
times in quick succession. Wait until the
SB-900 cools down.

Goes out

Goes out

Warning chime
rings twice.

The SB-900’s temperature has risen to a certain
level and the SB-900 enters protective shutdown
mode. Wait until the SB-900 cools down.