System Troubleshooting — Sprinklers

(continued)

PROBLEM

POSSIBLE CAUSE – CORRECTIVE ACTION

5.

Valve won't open

(a) Plugged controller discharge line or discharge port in pilot valve.

(Hyd. Normally Open

– Verify by checking for discharge at discharge line when station is activated. If no discharge,

734-X1-XX)

refer to Controller Service Manual.

6.

Valve won't close

(a) Leak in pilot valve assembly.

(Electric

– Replace pilot valve assembly.

734-X6-XXX)

(b) Plugged supply screen on piston.

– Clean or replace screen.

(c) Manual control selector on pilot valve assembly turned to "ON" position.

– Turn to "AUTO" position.

(d) Pilot Valve solenoid inoperative.

– Remove and replace.

7.

Valve won't open

(a) Control (field) wires severed.

(Electric 734-X6-XXX)

– Isolate and repair.

(b) Defective solenoid.

– Replace solenoid.

(c) No power to controller.

– Establish controller power.

(d) No power from controller to solenoid.

– Check for blown fuse and replace.

(e) Manual control selector on pilot valve assembly turned to "OFF" position.

– Turn to "AUTO" position.

(f)

No supply from main valve.
– Debris in control tube, main valve assembly and/or communication passages in body.

Flush thoroughly.

(g) Pilot Valve solenoid inoperative.

– Remove and replace.

8.

Sprinkler Weeping

(a) Damaged or blocked valve seat.

(Slow leak in valve)

– Remove blockage and, if necessary, replace valve assembly.

(b) Damaged piston seal or piston assembly.

– Replace valve assembly.

(c) Low pressure on supply line on hydraulic NO sprinklers.

– Check for low pressure reason and correct.

9.

Several valves on different

(a) Control tubing leak which lowers supply pressure to other stations.

stations fail to close

– Turn controller from station to station until a station is reached where only valves on that

(Hyd. Normally Open

station stay open. The leak would be in the tubing on that station. Isolate and repair.

734-X1-XX)

(b) Leak in supply line to controller.

– Verify by checking pressure in all control lines.

(c) Leak in controller pilot valve.

– Verify by constant discharge on controller. Refer to Controller Service Manual.

(d) Plugged supply line filter.

– Replace filter if more than 3 psi (0.21 kg/cm

2

) differential exists.

5