beautypg.com

Microwave circuit, Component testing – TurboChef Technologies C3/CMulti User Manual

Page 93

background image


Microwave Circuit

9-9

COMPONENT TESTING

WARNING!!

The microwave circuit cannot be serviced
with the unit on. The unit must be
disconnected from the power source.
Failure to do so could result in injury or
death.

WARNING!!

The HV Capacitor must be discharged
before proceeding.

WARNING!!
Do not attempt to measure the magnetron
anode or filament voltages. Failure to do
so could result in injury or death.

TRANSFORMER TESTING

1. Disconnect the power source and discharge

the capacitor.

2. Isolate the transformer from the circuit. (Wires

are labeled but remember where they go)

3. Check

impedance

of

the

primary

and

secondary windings. See TABLE 9-1 AND
FIGURE 9-4.

4. Filament winding should read less than 0.1

ohms.

5. Reconnect wires.

WARNING!!
When replacing the anode transformer,
remove

the

varnish

around

the

mounting

holes

to

insure

proper

grounding.

TRANSFORMER SPECIFICATIONS

Main Transformer (Anode)

Filament Transformer

Primary DCR

0.58 Ohm.

Primary DCR

(1-2) 23.2 Ohm
(1-3) 27.8 Ohm

Secondary DCR: (5-6) 46.39 Ohm

(5-7) 54.00 Ohm

Secondary DCR: (4-5) .020 Ohm

Input Voltage :

208-240 VAC, 50/60 HZ

Input Voltage :

200-208/240 ± 10%, 50/60 HZ

Input Current:

9.0 Amps RMS

Input Current:

0.42 Amps @ 208 VAC
0.35 Amps @ 240 VAC

Anode Voltage:

2400 VDC Peak @ 0.83 Amps

Filament Voltage: 4.6 VAC @ 14 Amps

TABLE 6 - 1 Transformer Specifications

DIODE TESTING

WARNING!!

DO NOT attempt to measure HV directly.

1. Isolate diode from circuit.

2. Connect the meter leads to the diode

terminals.

3. Resistance

readings

(open)

should

be

indicated in the reverse direction.

4. Resistance readings in the forward direction

may be indeterminate due to the number of
diodes in series making up this assembly.

5. If there is continuity in both directions (shorted

diode).

CAPACITOR TESTING

1. Disconnect the oven from the power source.

2. Isolate the capacitor from the circuit.

3. Fully discharge the capacitor.

4. Connect the ohmmeter between the capacitor

terminals. The meter should indicate a low
impedance and then slowly return to infinite
resistance.

5. Reverse the ohmmeter leads. Repeat step 4.

6. Check

each

terminal

to

case.

Infinite

resistance (open) should be indicated.

This manual is related to the following products: