8-10

Blower Motor Controller Fault Codes & Troubleshooting

NOTE: If no fault condition exists, the LED will be green. If a fault condition exists, the LED will flash

redhen a local keypad is not connected. All faults can be reset by cycling the reset control input,
pressing the stop key, or cycling power, except as noted in the Corrective Action column below.

NOTE: To recycle power, disconnect power for a full minute, or until the LED extinguishes, before
reapplying power.

Reliance Blower Motor Controller Fault Codes & Troubleshooting

# of

LED

Flashes

Fault

Description

Fault Cause

Corrective Action

2

Control Input

Illegal control input sequence

3–wire: Verify Start and Jog inputs

are not both ON

2–wire: Verify that only one input

(Forward, Reverse, or Jog) is ON

2

Function Loss

Start attempt while STOP

(function loss) input is off

Verify STOP (function loss) input

is ON before attempting to start
drive.

3

Under Voltage

Low input line

Temporary loss of input line

Check input line to verify voltage is

within operating specifications

4

Over Voltage

High input line

Decel time too fast

Overhauling load

Check input line to verify voltage is

within operating specifications

Increase decel time

5

Drive Overload

Excessive driven load

Reduce the load

5

Motor Overload

Excessive driven load

Verify P-02 is set correctly

Reduce the load.

Check for mechanical binding

6

Over Temperature

Operating environment is too hot

Fan is blocked or not operating

Excessive driven load

Verify the ambient temperature is

<50ºC

Verify clearance above/below

drive

Check for fan obstruction. Replace

if necessary

Reduce the carrier frequency (P–

64)

Reduce the load

7

Over Current

(300%)

Shaft rotation blocked

Excessive driven load

Output wiring is incorrect or

shorted

Check for obstructions to shaft

rotation or reduce excessive load

Increase accel/decel time

Verify output wiring is correct

8

Bad Keypad

Connection

Bad connection from keypad to

drive

Verify keypad is properly

connected to drive