Blower Circuit Defective Messages

SELF TEST

WHILE COOKING

CAUSE

CORRECTIVE ACTION

BLOWER STATUS
or "F1 BLOWER"

BLOWER STATUS
or "F1BLOWER"

Blower motor speed
controller not returning the
"running status command"

See status indicator A

Note: If the door is opening
intermittently, the blower
will cease to operate.

1) Verify jumper on P3 of control

board is present and placed
according to motor controller
(see wiring diagram section
for details).


Pins 1&2=Reliance Controller
Pins 2&3=Delta Controller

2) Check Auxillary fuses (refer to

schematic


3) Verify incoming voltage is

present on controller input
(200-240VAC).


4) Verify status indicator A is not

highlighted. (See Page 5-3)


5) Check

controller

output

voltage on motor controller
(see Table 8-1)


6) Check fault messages on

blower motor speed controller
(refer to appropriate controller
selection).


7) Check all connections in the

blower circuit (ribbon cables,
signal wires).


8) Check all interlock switches.

9) Verify motor shaft turns freely,
if

not

then

remove

motor

assembly and inspect wheel.