Heater Circuit Defective Messages

SELF TEST (STEST)

WHILE COOKING

(WARMING UP)

CAUSE

CORRECTIVE ACTION

THERMO OPEN

THERMO OPEN

HX Thermocouple amplifier
indicates open, (999

°

)."or"

CC Thermocouple amplifier
indicates open

1. Check Thermocouple connections on
I/O board connector (See I/O board
section for details) are not loose or
intermittently making contact with
mating connector.

2. Replace thermocouple.

HX RISE LOW

HX RISE LOW

1) During the warm up cycle if a
14

°

F rise is not detected within 5

minutes of initial warm-up, then
the controller displays "HX RISE
LOW".

2) HX Temperature failed to rise
14

°

F in 30 seconds during the

self-test mode.

1.

Check main internal circuit breaker.
If tripped, check the following
operation:

a) Interlock switches (Chapter 7)

b) Magnetron transformer (Page 9-8)

c) Hi-limit switch (See Figure 8-2)

2.

Check heater fuse (F3). If fuse is
blown check for short to chassis on
all heater wires.

3.

Check input current on heater
wires. (See Page 8-3)

4.

Check operation of the heater
relay. (See Page 8-3)

5.

Check blower operation (Page 8-9)

6.

Check crimp connections on
controller.

7.

Check HX Thermocouple.

LOW COOK TMP

(F3 LOW TEMP)

CC (Cooking Chamber)
temperature has dropped more
than 84

°

F (47

°

C) or more below

cook set point after 5 seconds or
more into cook cycle.

1.

Check main internal circuit breaker.
If tripped, check the following
operation:

a) Interlock switches (Chapter 7)

b) Magnetron transformer (Page 9-8)

c) Hi-limit switch. See Figure 8-2.

2.

Check blower operation. (Chapter
8-9)

3.

Check CC Thermocouple circuitry.

4.

Check Catalytic Converter (Page
8-2)

5.

Check debris catcher (pepperoni
catcher). See Figure 8-2

6.

Verify cooking chamber top air
nozzle holes are not clogged.

7.

Open door and run blower from 0%
to 100% and verify blower is
working properly (Air pressure).

8.

Verify oven software is greater
than Revision S (C3AD S).