Theory of Operation

4-3

Fault Code Messages Matrix

Old Error Code

New Error

Code

Warm-

Up

While

Cooking

Self-

Test

Reference

Chapter

BLOWER STATUS

F3 BLOWER

X

X

X

8

LOW COOK TMP

F2 LOW TEMP

X

8

LOW MAG CURR

F3 MAG CURR

X

X

9

DOOR MONITOR

F4 MONITOR

X

7

MAG OVER TMP

F5 MAG TEMP

X

X

X

9

ELEC OVR TMP

F6 EC TEMP

X

X

X

6

HX RISE LOW

Same

X

X

8

THERMO OPEN

Same

X

X

X

8

OVEN DOOR AJAR

Same

X

X

X

7

EC TEMP HIGH

F6 EC TEMP

X

X

X

6

CLOSE OVEN
DOOR

same

X

X

X

7

TABLE 4-1

Notes:

1. All Fault Codes listed in BOLD will terminate a Cook Cycle upon discovery.

2. Any fault occurrence during Cook mode will be logged in the Fault Counter.

3. ELEC OVR TMP/EC TEMP HIGH/F6 fault code will not terminate a cook cycle,
however it will alert the user of a possible air circulation problem (Page 6-10)