Theory of operation, Fault code messages matrix – TurboChef Technologies C3/CMulti User Manual
Page 25
Theory of Operation
4-3
Fault Code Messages Matrix
Old Error Code
New Error
Code
Warm-
Up
While
Cooking
Self-
Test
Reference
Chapter
BLOWER STATUS
F3 BLOWER
X
X
X
8
LOW COOK TMP
F2 LOW TEMP
X
8
LOW MAG CURR
F3 MAG CURR
X
X
9
DOOR MONITOR
F4 MONITOR
X
7
MAG OVER TMP
F5 MAG TEMP
X
X
X
9
ELEC OVR TMP
F6 EC TEMP
X
X
X
6
HX RISE LOW
Same
X
X
8
THERMO OPEN
Same
X
X
X
8
OVEN DOOR AJAR
Same
X
X
X
7
EC TEMP HIGH
F6 EC TEMP
X
X
X
6
CLOSE OVEN
DOOR
same
X
X
X
7
TABLE 4-1
Notes:
1. All Fault Codes listed in BOLD will terminate a Cook Cycle upon discovery.
2. Any fault occurrence during Cook mode will be logged in the Fault Counter.
3. ELEC OVR TMP/EC TEMP HIGH/F6 fault code will not terminate a cook cycle,
however it will alert the user of a possible air circulation problem (Page 6-10)