TurboChef Technologies, Inc. C Series

8 - 9

# of

LED

Flashes

Fault

Description

Fault Cause

Corrective Action

9

Negative Slope

Conflicting parameter values

Adjust values of parameters P–50

through P–54

Phase U

Phase V


Ground Short

Phase W

Verify output wiring is correct

Verify output phase is not

grounded

Verify motor is not damaged

Phase U-V

Phase U-W

10

Phase to Phase

Short

Phase V-W

Verify output wiring is correct

Verify motor is not damaged

11

Checksum Failure

Parameter value out of range

Load default parameter values (P–

60=1), then cycle power. If fault
persists, replace drive.

12

Microprocessor

Fault

Internal processor error

Cycle power. If fault persists,

replace drive.

TABLE 5 - 2 Reliance Blower Motor Controller Fault Codes & Troubleshooting