2 500-3x-3x series control panel connections – Trilogy Touch Technology Trilogy Commander Digital Intercom 9 User Manual
Page 69

Commander Installation Guide
Trilogy Communications Limited
Page 69 of 81
Issue 9
8.5.2.2 500-3x-3x Series Control Panel Connections
Matrix – D9 Fixed Plug
Pin
Function
1 NC
(Screen)
2 Data
Out-
3 Data
In-
4 Audio
Out-
5 Audio
In-
6
Data Out +
7
Data In +
8 Audio
Out
9
Audio In +
Test Port– D9 Fixed Socket
Pin
Function
1 Analyse
Input
2
Enable Remote Boot
3 Ground
4
Transputer Link Out +
5
Transputer Link In +
6 Error
signal
Out
7 Reset
In
8
Transputer Link Out-
9
Transputer Link In-
Headset - 5 Pin XLR Fixed Socket
(Front panel)
Pin
Function
1
Mic IN (Screen)
2 Mic
IN
3
Headset Gnd
4 Headset
Out
5 Headset
Out
Expansion Port– D9 Fixed Socket
Pin
Function
1 Analyse
Input
2
Enable Remote Boot
3 Ground
4
Transputer Link Out +
5
Transputer Link In +
6 Error
signal
in
7 Reset
Out
8
Transputer Link Out-
9
Transputer Link In-
Foot Switch - D9 Fixed Socket
Pin
Function
1
Foot Switch Input
2 No
Connection
3 Chassis
Ground
4 No
Connection
5 No
Connection
6 Ground
7 No
Connection
8 No
Connection
9 No
Connection
GPIO (Local logic in and out) - D9 Fixed Socket
Pin
Function
Notes
1 Ground
2 Logic
Input
1
3 Logic
Input
2
4
Logic 2 Out Common
5
Internal +5V (Out)
Protected with series 44R & 1N4002 diode.
6
Logic Output 1
7
Logic 1 Out Common
8
Logic Output 2
9
Logic Input +VCC
NB Pin 9 may be driven by external voltage (With dropper