9 500-31-60 standard facility 16 key control panel, 1 specification, Rear panel layout – Trilogy Touch Technology Trilogy Commander Digital Intercom 9 User Manual
Page 46: Panel. see section 5.9

Commander Installation Guide
Page 46 of 81
Trilogy Communications Limited
Issue 9
5.9 500-31-60 STANDARD FACILITY 16 KEY CONTROL PANEL
The 500-31-60 panel provides 16 programmable lever keys in a 2U rack mount chassis. For
information on programming the software driven “cut switch” operation, see section 10.3.
5.9.1 SPECIFICATION
Dimensions
485mm wide x 88.9mm high x 80mm deep
(approx. including PSU and mating connectors).
19” x 2RU rack mounting
Mains Input
90 – 250 V ac, 50-60Hz
Current Consumption
150mA @ 90V, 50mA @ 250V
5.9.2 REAR PANEL LAYOUT
Connector types:
Matrix
RJ 45 socket
GPIO
D9 Fixed Socket
Audio I/O
D15 Fixed Socket
Footswitch
D9 Fixed Socket
Matrix – RJ-45 fixed socket on panel
RJ-45
Pin
Function
1
Panel Data out +
Pair
1
2
Panel Data out -
3
Panel Data In +
Pair
2
6
Panel Data In -
5
Panel Audio out +
Pair
3
4
Panel Audio out -
7
Panel Audio in +
Pair
4
8
Panel Audio in -
Cable
Screen
Headset - 5 Pin XLR Fixed Socket (front
panel)
Pin
Function
1
Mic IN (Screen)
2 Mic
IN
3
Headset Gnd
4 Headset
Out
5 Headset
Out
Foot Switch - D9 Fixed Socket
Pin
Function
1
Foot Switch Input
2 No
Connection
3 Chassis
Ground
4
Reserved
5
Reserved
6 Ground
7
Reserved
8
Reserved
9
Reserved