beautypg.com

Lamp replacement (continued) – Toshiba TDP-MT200 User Manual

Page 34

background image

34

Lamp replacement (Continued)

1

Unplug power cord.

2

Wait until lamp is sufficiently cooled.

Wait for at least 1 hour.

3

Remove the lamp cover.

Loosen the 1 screw, then pull up to the direc-
tion of the arrow with your fingers as shown to
remove the lamp cover. Use care to avoid any
damage to nails and/or tip of your finger(s). If
you have any difficulty in removal, you can use
a screwdriver or any other smaller tool for your
convenience.

4

Pull out the lamp.

Loosen the 2 screws holding the lamp in place,
and pull up the handle to remove the lamp.

5

Mount the new lamp.

Align the orientation, press down until the bottom is
reached, and lock in place using the two lamp
locking screws.

6

Replace the lamp cover.

Align the cover, and press it in, then tighten the
screws loosened in step

3

until the lamp cover is

no longer loose.

7

Reset the lamp timer.

See the lamp’s manual for instructions on resetting
the lamp timer.

Notes and Precautions

• Press the

button twice to display (a rough guide) the time of lamp use, the Lamp time

item, in the Status display menu.

p.32

• It is recommended that the lamp be replaced after 2,000 hours of use. When Lamp time

reaches 2,000 hours, the

icon and a message will appear. This display disappears

when you press

button.

• Attach the lamp cover correctly so that it is not loose. If it is not attached correctly, the

lamp may fail to come on

p.36

, and the lamp’s lifetime may be shortened.

• Always replace the lamp with a new one.
• The lamp is made out of glass. Do not touch the glass surface with your bare hands,

bang it, or scratch it. (Dirt, jolts, scratches and the like could break the lamp.)

2

1

2

1

1

2

3

4

5

Lamp cover