beautypg.com

Restoring factory default setting – TOA Electronics A-9060S User Manual

Page 84

background image

84

Step 1. Hold down the Utility menu key for 2 seconds or more

when in normal use state.

Step 2. Using the Parameter setting knob, select UTILITY

SETTING, then press the Right shift key.

Step 3. Using the Parameter setting knob or UP/Down shift

key, select MEMORY, then press the Right shift key.

Step 4. Press the Enter key when the "INITIALIZE OK?"

indication is displayed.

To cancel initialization, press the Left shift key or
Escape/Back key to revert back to the previous
screen.

Follow the procedures below to return all settings to default values while using the unit in the matrix mode.
Details of the default values are shown on

the next page, "Default Setting Table."

Normal operation mode

I N I T I A L I Z E

O K ?

I N P U T – S E T T I N G

Setting menu screen

U T I L I T Y – S E T T I N G

U T I L I T Y

C - I N

U T I L I T Y

M E M O R Y

PARAMETER

U T I L I T Y

ENTER

1

2

3

4

PARAMETER

or

14. RESTORING FACTORY DEFAULT SETTING