beautypg.com

2 system buzzer, 3 led, The led features are describing as follows – Thecus Technology i Series User Manual

Page 14

background image



Caution

Before power off, it is better to execute “Shutdown” to flush
the data from cache to physical disks.


2.4.2

System buzzer


The system buzzer features are describing in the following:

1. The system buzzer alarms 1 second when system boots up

successfully.

2. The system buzzer alarms continuously when there is error level event

happened. The alarm will be stopped after mute.

3. The alarm will be muted automatically when the error situation is

resolved. E.g., when RAID 5 is degraded and alarm rings immediately,
after user changes/adds one physical disk for rebuilding, and when the
rebuilding is done, the alarm will be muted automatically.


2.4.3

LED

The LED features are describing as follows:

1. Marquee/Disk Status/Disk Rebuilding LED: The Marquee/Disk

Status/Disk Rebuilding LEDs are displayed in the same LEDs. The
LEDs behave for different functions in different stages.

I.

Marquee LEDs

: When system powers on and succeeds to boot

up, the Marquee LED acts until the system is booting successful.

II.

Disk status LEDs

: the LEDs reflect the disk status for the tray.

Only On/Off situation.

III.

Disk rebuilding LEDs

: the LEDs are blinking when the disks are

under rebuilding.

2. Disk Access LED: Hardware activated LED when accessing disks (IO).
3. Disk Power LED: Hardware activated LED when the disks are plugged

in and powered.

4. System status LED: Used to reflect the system status by turn on the

LED when error occurs or RAID malfunctioning happens.

5. Management LAN port LED: GREEN LED is for LAN transmit/receive

indication. ORANGE LED is for LAN port 10/100 LINK indication.

6. BUSY LED: Hardware activated LED when the front-end channel is

busy.

7. POWER LED: Hardware activated LED when system is powered on.

- 14 -