beautypg.com

Chassis – Transition Networks POINTSYSTEM CPSMC0810-100 User Manual

Page 18

background image

18

CPSMC08xx-100 PointSystem

Chassis

chassis

4.1.3

Grounding Lugs

The CPSMC08xx-100 comes equipped with grounding lugs, which are provided for
a grounding conductor wire terminated with a two-hole, compression-type,
grounding connector
. The grounding wire -- which must be a copper conductor --
is not included with the chassis and must be provided by the customer/installer.

The electrical conducting path from the chassis must:

Flow via the grounding lugs to the Common Bonding Network (CBN) for
telecom installations; or to an alternate approved grounding system (if required)
for non-telecom installations,

Be of sufficiently low impedance to conduct fault currents likely to be imposed
on the chassis, and

Enable proper operation of any over-current protection devices.

The two-hole, compression-type, grounding connector must be fastened to the
grounding lugs with the enclosed, anti-rotation star-washers and lug-nut fasteners
.
The required torque to the fasteners is specified by the connector’s manufacturer.

To properly ground the CPSMC08xx-100 chassis:

1. Obtain one (1) properly-terminated, grounding conductor (12 AWG copper

wire gauge or larger) with a two-hole, compression-type, grounding connector.
Note the manufacturer's applied torque that is required for the connector.

2. Attach the grounding conductor to the chassis by placing the two-hole,

compression-type connector onto the grounding lugs and fasten with
appropriate lock-washers and lug-nuts at the proper torque.

3. Attach the opposite end of the properly-terminated grounding conductor to the

Common Bonding Network (CBN) for telecom installations, or to an approved
grounding system (if required) for non-telecom installations.

24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600

Grounding Lugs

CBN (for telecom installation)
or Earth Ground

Grounding Wire with a

two-hole, compression-type

grounding connector

3/4-inch

spacing

Grounding lugs

(6-32, 1/8" diam.)

Two-hole, compression-type

grounding connector (not included)

Star washer (included)

Lug nuts (included)